These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Clinical comparison of pascal dynamic contour tonometry and goldmann applanation tonometry in asymmetric open-angle glaucoma. Sullivan-Mee M, Halverson KD, Qualls C. J Glaucoma; 2007 Dec; 16(8):694-9. PubMed ID: 18091457 [Abstract] [Full Text] [Related]
4. Central corneal thickness and intraocular pressure in a Mongolian population. Foster PJ, Baasanhu J, Alsbirk PH, Munkhbayar D, Uranchimeg D, Johnson GJ. Ophthalmology; 1998 Jun; 105(6):969-73. PubMed ID: 9627643 [Abstract] [Full Text] [Related]
5. [Intraocular pressure and prevalence of occult glaucoma in a village of Murcia]. Zafra Pérez JJ, Villegas Pérez MP, Canteras Jordana M, Miralles De Imperial J. Arch Soc Esp Oftalmol; 2000 Mar; 75(3):171-8. PubMed ID: 11151145 [Abstract] [Full Text] [Related]
6. [Concordance of nictemeral IOP variations between fellow eyes in glaucoma and non glaucoma patients]. Chiseliţă D, Moţoc I, Danielescu C. Oftalmologia; 2008 Mar; 52(3):102-9. PubMed ID: 19149128 [Abstract] [Full Text] [Related]
7. [Intraocular pressure difference in Goldmann applanation tonometry versus a transpalpebral tonometer TGDc-01"PRA" in glaucoma patients]. Schlote T, Landenberger H. Klin Monbl Augenheilkd; 2005 Feb; 222(2):123-31. PubMed ID: 15719316 [Abstract] [Full Text] [Related]
9. The prevalence of primary open-angle glaucoma in Japanese: the Tajimi Study. Iwase A, Suzuki Y, Araie M, Yamamoto T, Abe H, Shirato S, Kuwayama Y, Mishima HK, Shimizu H, Tomita G, Inoue Y, Kitazawa Y, Tajimi Study Group, Japan Glaucoma Society. Ophthalmology; 2004 Sep; 111(9):1641-8. PubMed ID: 15350316 [Abstract] [Full Text] [Related]
10. [Intraocular pressure measurements with the Proview self-tonometer in comparison of Goldmann applanation tonometry in healthy and glaucomatous eyes]. Meyer MW, Yevelenko V, Hoy L, Meyer A, Erb C. Klin Monbl Augenheilkd; 2006 Nov; 223(11):899-903. PubMed ID: 17131250 [Abstract] [Full Text] [Related]
11. Intraocular pressure difference in Goldmann applanation tonometry versus Perkins hand-held applanation tonometry in overweight patients. dos Santos MG, Makk S, Berghold A, Eckhardt M, Haas A. Ophthalmology; 1998 Dec; 105(12):2260-3. PubMed ID: 9855157 [Abstract] [Full Text] [Related]
12. Intraocular pressure elevation within the first 24 hours after cataract surgery in patients with glaucoma or exfoliation syndrome. Levkovitch-Verbin H, Habot-Wilner Z, Burla N, Melamed S, Goldenfeld M, Bar-Sela SM, Sachs D. Ophthalmology; 2008 Jan; 115(1):104-8. PubMed ID: 17561259 [Abstract] [Full Text] [Related]
13. Diurnal intraocular pressure fluctuation and associated risk factors in eyes with angle closure. Baskaran M, Kumar RS, Govindasamy CV, Htoon HM, Wong CY, Perera SA, Wong TT, Aung T. Ophthalmology; 2009 Dec; 116(12):2300-4. PubMed ID: 19850348 [Abstract] [Full Text] [Related]
14. The accuracy of continued clinical use of goldmann applanation tonometers with known calibration errors. Sandhu SS, Chattopadhyay S, Amariotakis GA, Skarmoutsos F, Birch MK, Ray-Chaudhuri N. Ophthalmology; 2009 Jan; 116(1):9-13. PubMed ID: 18801579 [Abstract] [Full Text] [Related]
15. [Normal intraocular pressure values in the Czech population]. Hornová J. Cesk Slov Oftalmol; 1997 May; 53(2):88-93. PubMed ID: 9296866 [Abstract] [Full Text] [Related]
18. Intraocular pressure control following phacoemulsification in patients with chronic angle closure glaucoma. Euswas A, Warrasak S. J Med Assoc Thai; 2005 Nov; 88 Suppl 9():S121-5. PubMed ID: 16681063 [Abstract] [Full Text] [Related]