These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


63 related items for PubMed ID: 8924664

  • 1. [Influence of respiration and pulsatility on the accuracy of MR-phase contrast flow measurements: "in vitro" evaluation].
    Schoenenberger AW, Debatin JF.
    Rofo; 1996 Aug; 165(2):130-6. PubMed ID: 8924664
    [Abstract] [Full Text] [Related]

  • 2. Quantitative phase-contrast flow MRI measurements in the presence of a second vessel closely positioned to the examined vessel.
    Lagerstrand KM, Vikhoff-Baaz B, Starck G, Forssell-Aronsson E.
    J Magn Reson Imaging; 2006 Feb; 23(2):156-62. PubMed ID: 16416442
    [Abstract] [Full Text] [Related]

  • 3. Cine flow measurements using phase contrast with undersampled projections: in vitro validation and preliminary results in vivo.
    Wentland AL, Korosec FR, Vigen KK, Wieben O, Fine JP, Grist TM.
    J Magn Reson Imaging; 2006 Oct; 24(4):945-51. PubMed ID: 16969791
    [Abstract] [Full Text] [Related]

  • 4. In vitro validation of phase-contrast flow measurements at 3 T in comparison to 1.5 T: precision, accuracy, and signal-to-noise ratios.
    Lotz J, Döker R, Noeske R, Schüttert M, Felix R, Galanski M, Gutberlet M, Meyer GP.
    J Magn Reson Imaging; 2005 May; 21(5):604-10. PubMed ID: 15834905
    [Abstract] [Full Text] [Related]

  • 5. [Flow quantification with magnetic resonance: preliminary results with phase contrast technique].
    Pavone P, Laghi A, Catalano C, Paneblanco V, Scipioni A, Di Girolamo M, Kayal R, Passariello R.
    Radiol Med; 1996 Sep; 92(3):218-22. PubMed ID: 8975305
    [Abstract] [Full Text] [Related]

  • 6. Zero filled partial fourier phase contrast MR imaging: in vitro and in vivo assessment.
    Szarf G, Dori Y, Rettmann D, Tekes A, Nasir K, Amado L, Foo TK, Bluemke DA.
    J Magn Reson Imaging; 2006 Jan; 23(1):42-9. PubMed ID: 16315213
    [Abstract] [Full Text] [Related]

  • 7. Comparison of breath-hold 2D phase-contrast with non breath-hold cine phase-contrast MRA in the assessment of azygos venous blood flow in portal hypertension.
    Ng WH, Chan YL, Sung JY, Lee YT, Lee SF, Chung SS.
    MAGMA; 2004 Apr; 16(5):211-7. PubMed ID: 15022053
    [Abstract] [Full Text] [Related]

  • 8. Regularization of flow streamlines in multislice phase-contrast MR imaging.
    Fatouraee N, Amini AA.
    IEEE Trans Med Imaging; 2003 Jun; 22(6):699-709. PubMed ID: 12872945
    [Abstract] [Full Text] [Related]

  • 9. [2D-phase contrast flow evaluation and contrast-enhanced MR angiography for perioperative assessment of internal mammary artery grafts].
    Stauder NI, Miller S, Scheule AM, Brechtel K, Eckstein FS, Hahn U, Kramer U, Duda SH, Claussen CD.
    Rofo; 2001 Sep; 173(9):790-7. PubMed ID: 11582557
    [Abstract] [Full Text] [Related]

  • 10. High-resolution magnetic resonance angiography of the lower extremities with a dedicated 36-element matrix coil at 3 Tesla.
    Kramer H, Michaely HJ, Matschl V, Schmitt P, Reiser MF, Schoenberg SO.
    Invest Radiol; 2007 Jun; 42(6):477-83. PubMed ID: 17507821
    [Abstract] [Full Text] [Related]

  • 11. [Contribution of early systole to total antegrade flow volume in breath-hold phase-contrast flow measurements].
    Kunz RP, Oellig F, Krummenauer F, Oberholzer K, Neeb D, Vomweg TW, Horstick G, Kreitner KF.
    Rofo; 2005 May; 177(5):637-45. PubMed ID: 15871078
    [Abstract] [Full Text] [Related]

  • 12. Comparative velocity investigations in cerebral arteries and aneurysms: 3D phase-contrast MR angiography, laser Doppler velocimetry and computational fluid dynamics.
    Hollnagel DI, Summers PE, Poulikakos D, Kollias SS.
    NMR Biomed; 2009 Oct; 22(8):795-808. PubMed ID: 19412933
    [Abstract] [Full Text] [Related]

  • 13. Flow velocity and volume measurement of superior and inferior mesenteric artery with cine phase contrast magnetic resonance imaging.
    Naganawa S, Cooper TG, Jenner G, Potchen EJ, Ishigaki T.
    Radiat Med; 1994 Oct; 12(5):213-20. PubMed ID: 7863025
    [Abstract] [Full Text] [Related]

  • 14. Correction for displacement artifacts in 3D phase contrast imaging.
    Thunberg P, Wigström L, Ebbers T, Karlsson M.
    J Magn Reson Imaging; 2002 Nov; 16(5):591-7. PubMed ID: 12412037
    [Abstract] [Full Text] [Related]

  • 15. [Cardiac MR flowmetry: experimental validation and results in patients with operated heart defects].
    Hosten N, Gutberlet M, Kühne T, Oellinger H, Vogel M, Böckel T, Böck J, Frank J.
    Rofo; 1998 May; 168(5):480-7. PubMed ID: 9617365
    [Abstract] [Full Text] [Related]

  • 16. Numerical and experimental study of a novel phase contrast magnetic resonance (PC-MR) imaging technique: sparse interleaved referencing PC-MR imaging.
    Li L, Doyle M, Rayarao G, Biederman RW, Anayiotos A.
    J Magn Reson Imaging; 2008 Apr; 27(4):898-907. PubMed ID: 18383251
    [Abstract] [Full Text] [Related]

  • 17. [Experimental evaluation of vessel diameter from 0.3 to 8 mm in CE MR angiography].
    Vosshenrich R, Engeroff B, Müller C, Fischer U, Grabbe E.
    Rofo; 2001 Sep; 173(9):842-7. PubMed ID: 11582565
    [Abstract] [Full Text] [Related]

  • 18. Effect of flip angle on volume flow measurement with nontriggered phase-contrast MR: In vivo evaluation in carotid and basilar arteries.
    Tanaka H, Fujita N, Takahashi H, Sakai M, Nagao T, Murase K, Nakamura H.
    J Magn Reson Imaging; 2009 May; 29(5):1218-23. PubMed ID: 19388100
    [Abstract] [Full Text] [Related]

  • 19. [Myocardial microcirculation in humans--new approaches using MRI].
    Wacker CM, Bauer WR.
    Herz; 2003 Mar; 28(2):74-81. PubMed ID: 12669220
    [Abstract] [Full Text] [Related]

  • 20. Flow quantification and analysis methods.
    Pelc NJ.
    Magn Reson Imaging Clin N Am; 1995 Aug; 3(3):413-24. PubMed ID: 7584247
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 4.