These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
224 related items for PubMed ID: 8964992
41. Durability of pericardial versus porcine aortic valves. Gao G, Wu Y, Grunkemeier GL, Furnary AP, Starr A. J Am Coll Cardiol; 2004 Jul 21; 44(2):384-8. PubMed ID: 15261935 [Abstract] [Full Text] [Related]
42. The Carpentier-Edwards supraannular porcine bioprosthesis. A new generation tissue valve with excellent intermediate clinical performance. Jamieson WR, Munro AI, Miyagishima RT, Burr LH, Gerein AN, Janusz MT, Tyers GF, Allen P. J Thorac Cardiovasc Surg; 1988 Oct 21; 96(4):652-66. PubMed ID: 3172812 [Abstract] [Full Text] [Related]
43. Clinical experience with the Carpentier-Edwards porcine bioprosthesis: short-term results (from 2 to 4.5 years). Gallo I, Ruiz B, Duran CM. Thorac Cardiovasc Surg; 1983 Oct 21; 31(5):277-81. PubMed ID: 6196860 [Abstract] [Full Text] [Related]
44. Aortic valve replacement with the Hancock standard, Björk-Shiley, and Lillehei-Kaster prostheses. A comparison based on follow-up from 1 to 15 years. Milano AD, Bortolotti U, Mazzucco A, Guerra F, Magni A, Gallucci V. J Thorac Cardiovasc Surg; 1989 Jul 21; 98(1):37-47. PubMed ID: 2739424 [Abstract] [Full Text] [Related]
45. Björk-Shiley and Carpentier-Edwards valves. A comparative analysis. Nashef SA, Sethia B, Turner MA, Davidson KG, Lewis S, Bain WH. J Thorac Cardiovasc Surg; 1987 Mar 21; 93(3):394-404. PubMed ID: 3821149 [Abstract] [Full Text] [Related]
46. Durability of porcine valves at fifteen years in a representative North American patient population. Burdon TA, Miller DC, Oyer PE, Mitchell RS, Stinson EB, Starnes VA, Shumway NE. J Thorac Cardiovasc Surg; 1992 Feb 21; 103(2):238-51; discussion 251-2. PubMed ID: 1735989 [Abstract] [Full Text] [Related]
48. [Double valve replacement with mechanical prostheses--an operative results]. Saigenji H, Toyohira H, Shimokawa S, Moriyama Y, Yamaoka A, Taira A. Nihon Kyobu Geka Gakkai Zasshi; 1995 Sep 21; 43(9):1600-4. PubMed ID: 8530844 [Abstract] [Full Text] [Related]
49. Carpentier-Edwards standard and supra-annular porcine bioprostheses: 10 year comparison of structural valve deterioration. Jamieson WR, Burr LH, Tyers GF, Munro AI. J Heart Valve Dis; 1994 Jan 21; 3(1):59-65. PubMed ID: 8162218 [Abstract] [Full Text] [Related]
50. Long-term follow up of the Biocor porcine bioprosthesis in the mitral position. Pomerantzeff PM, Brandão CM, Albuquerque JM, Stolf NA, Grinberg M, Oliveira SA. J Heart Valve Dis; 2006 Nov 21; 15(6):763-6; discussion 766-7. PubMed ID: 17152783 [Abstract] [Full Text] [Related]
51. Aortic and mitral valve replacement in children: is there any role for biologic and bioprosthetic substitutes? Alsoufi B, Manlhiot C, McCrindle BW, Canver CC, Sallehuddin A, Al-Oufi S, Joufan M, Al-Halees Z. Eur J Cardiothorac Surg; 2009 Jul 21; 36(1):84-90; discussion 90. PubMed ID: 19369085 [Abstract] [Full Text] [Related]
52. Morphologic findings in explanted Hancock II porcine bioprostheses. Butany J, Yu W, Silver MD, David TE. J Heart Valve Dis; 1999 Jan 21; 8(1):4-15. PubMed ID: 10096476 [Abstract] [Full Text] [Related]
54. Late outcomes for aortic valve replacement with the Carpentier-Edwards pericardial bioprosthesis: up to 17-year follow-up in 1,000 patients. McClure RS, Narayanasamy N, Wiegerinck E, Lipsitz S, Maloney A, Byrne JG, Aranki SF, Couper GS, Cohn LH. Ann Thorac Surg; 2010 May 21; 89(5):1410-6. PubMed ID: 20417753 [Abstract] [Full Text] [Related]
55. Heart valve replacement with the Sorin tilting-disc prosthesis. A 10-year experience. Milano A, Bortolotti U, Mazzucco A, Mossuto E, Testolin L, Thiene G, Gallucci V. J Thorac Cardiovasc Surg; 1992 Feb 21; 103(2):267-75. PubMed ID: 1735992 [Abstract] [Full Text] [Related]
56. [Comparative analysis of mechanical and biological prosthetic valves after isolated valve replacement--cooperative study on total 1281 patients]. Nakano S, Kawashima Y, Komatsu S, Sakai K, Eguchi S, Aosaki M, Misaki T, Ohara K, Tokunaga K. Nihon Kyobu Geka Gakkai Zasshi; 1989 Mar 21; 37(3):423-30. PubMed ID: 2671191 [Abstract] [Full Text] [Related]
57. [Clinical experience with the omnicarbon valve prosthesis]. Ohtaki M, Kawashima M, Miki T, Yamaguchi A, Tamura H, Kitamura N. Nihon Kyobu Geka Gakkai Zasshi; 1992 Dec 21; 40(12):2131-5. PubMed ID: 1491190 [Abstract] [Full Text] [Related]
58. Carpentier-Edwards pericardial bioprosthesis in aortic or mitral position: a 12-year experience. Neville PH, Aupart MR, Diemont FF, Sirinelli AL, Lemoine EM, Marchand MA. Ann Thorac Surg; 1998 Dec 21; 66(6 Suppl):S143-7. PubMed ID: 9930436 [Abstract] [Full Text] [Related]
59. [Valvular surgery for the patients 70 years old or older]. Saigenji H, Toyohira H, Shimokawa S, Moriyama Y, Toda R, Fukuda S, Masuda H, Yamashita T, Taira A. Nihon Kyobu Geka Gakkai Zasshi; 1995 Jan 21; 43(1):32-6. PubMed ID: 7884258 [Abstract] [Full Text] [Related]
60. Randomised, prospective evaluation of a new pericardial heart valve: outcome after seven years. Wheatley DJ, Tolland MM, Pathi V, Bernacca GM, Murray GD, Davidson KG, Breeze P, Cobbe SM. Eur J Cardiothorac Surg; 1995 Jan 21; 9(5):259-67; discussion 267-8. PubMed ID: 7662379 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]