These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
179 related items for PubMed ID: 9039518
1. Surfactant proteins and stable microbubbles in tracheal aspirates of infants with respiratory distress syndrome: relation to the degree of respiratory failure and response to exogenous surfactant. Chida S, Fujiwara T, Konishi M, Shimada S, Takahashi A. Eur J Pediatr; 1997 Feb; 156(2):131-8. PubMed ID: 9039518 [Abstract] [Full Text] [Related]
2. Surfactant apoprotein A (SP-A) in tracheal aspirates of newborn infants with RDS. Eguchi H, Koyama N, Tanaka T, Kamiya K, Ogawa Y. Acta Paediatr Jpn; 1991 Oct; 33(5):649-54. PubMed ID: 1799120 [Abstract] [Full Text] [Related]
3. Usefulness of stable microbubble test of tracheal aspirate for the diagnosis of neonatal respiratory distress syndrome. Boo NY, Cheong KB, Cheong SK, Lye MS, Zulfiqar MA. J Paediatr Child Health; 1997 Aug; 33(4):329-34. PubMed ID: 9323622 [Abstract] [Full Text] [Related]
4. Measurement of pulmonary status and surfactant protein levels during dexamethasone treatment of neonatal respiratory distress syndrome. Wang JY, Yeh TF, Lin YC, Miyamura K, Holmskov U, Reid KB. Thorax; 1996 Sep; 51(9):907-13. PubMed ID: 8984701 [Abstract] [Full Text] [Related]
5. Surfactant protein A in the course of respiratory distress syndrome. Stevens PA, Schadow B, Bartholain S, Segerer H, Obladen M. Eur J Pediatr; 1992 Aug; 151(8):596-600. PubMed ID: 1505580 [Abstract] [Full Text] [Related]
6. Stable microbubble test on tracheal aspirate for the diagnosis of respiratory distress syndrome. Eckert Seitz E, Fiori HH, Luz JH, Fiori RM. Biol Neonate; 2005 Aug; 87(2):140-4. PubMed ID: 15637456 [Abstract] [Full Text] [Related]
7. Surfactant protein A and saturated phosphatidylcholine in respiratory distress syndrome. Moya FR, Montes HF, Thomas VL, Mouzinho AM, Smith JF, Rosenfeld CR. Am J Respir Crit Care Med; 1994 Dec; 150(6 Pt 1):1672-7. PubMed ID: 7952631 [Abstract] [Full Text] [Related]
8. Repeat surfactant therapy for postsurfactant slump. Katz LA, Klein JM. J Perinatol; 2006 Jul; 26(7):414-22. PubMed ID: 16724122 [Abstract] [Full Text] [Related]
9. Surfactant-associated proteins in tracheal aspirates of infants with respiratory distress syndrome after surfactant therapy. Chida S, Phelps DS, Cordle C, Soll R, Floros J, Taeusch HW. Am Rev Respir Dis; 1988 Apr; 137(4):943-7. PubMed ID: 3355003 [Abstract] [Full Text] [Related]
10. Treatment with exogenous surfactant stimulates endogenous surfactant synthesis in premature infants with respiratory distress syndrome. Bunt JE, Carnielli VP, Janssen DJ, Wattimena JL, Hop WC, Sauer PJ, Zimmermann LJ. Crit Care Med; 2000 Oct; 28(10):3383-8. PubMed ID: 11057790 [Abstract] [Full Text] [Related]
11. The stable microbubble test on tracheal aspirate samples from newborn babies for diagnosis of surfactant deficiency and/or surfactant malfunction. Friedrich W, Haufe M, Schmalisch G, Wauer RR. Biol Neonate; 1998 Oct; 73(1):10-8. PubMed ID: 9458937 [Abstract] [Full Text] [Related]
12. Effects of Two Different Exogenous Surfactant Preparations on Serial Peripheral Perfusion Index and Tissue Carbon Monoxide Measurements in Preterm Infants with Severe Respiratory Distress Syndrome. Terek D, Gonulal D, Koroglu OA, Yalaz M, Akisu M, Kultursay N. Pediatr Neonatol; 2015 Aug; 56(4):248-55. PubMed ID: 25603725 [Abstract] [Full Text] [Related]
13. Patent ductus arteriosus hemodynamics in very premature infants treated with poractant alfa or beractant for respiratory distress syndrome. Fujii A, Allen R, Doros G, O'Brien S. J Perinatol; 2010 Oct; 30(10):671-6. PubMed ID: 20336077 [Abstract] [Full Text] [Related]
14. Surfactant therapy in neonates with respiratory failure due to haemorrhagic pulmonary oedema. Amizuka T, Shimizu H, Niida Y, Ogawa Y. Eur J Pediatr; 2003 Oct; 162(10):697-702. PubMed ID: 12898240 [Abstract] [Full Text] [Related]
15. Evaluation of surfactant function at birth determined by the stable microbubble test in term and near term infants with respiratory distress. Fiori HH, Henn R, Baldisserotto M, Bica IG, Fiori RM. Eur J Pediatr; 2004 Aug; 163(8):443-8. PubMed ID: 15185148 [Abstract] [Full Text] [Related]