These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


183 related items for PubMed ID: 9052372

  • 1. Single therapeutic catheterization to treat coexisting coarctation of the aorta and patent ductus arteriosus.
    Ing FF, McMahon WS, Johnson GL, Vick GW, Mullins CE.
    Am J Cardiol; 1997 Feb 15; 79(4):535-7. PubMed ID: 9052372
    [Abstract] [Full Text] [Related]

  • 2. Successful transcatheter balloon dilatation of coarctation of aorta and coil occlusion of patent ductus arteriosus in a single catheterization procedure.
    Celebi A, Yalçin Y, Erdem A, Zeybek C, Akdeniz C, Polat TB.
    Turk J Pediatr; 2007 Feb 15; 49(1):94-7. PubMed ID: 17479653
    [Abstract] [Full Text] [Related]

  • 3. Sequential transcatheter treatment of combined coarctation of aorta and persistent ductus arteriosus.
    Pavlovic D, Suárez de Lezo J, Medina A, Romero M, Hernández E, Pan M, Tejero I, Melian F.
    Am Heart J; 1992 Jan 15; 123(1):249-50. PubMed ID: 1530896
    [No Abstract] [Full Text] [Related]

  • 4. Simultaneous stent implantation for coarctation of the aorta and closure of patent ductus arteriosus using the Amplatzer duct occluder.
    Hakim F, Hawelleh AA, Goussous Y, Hijazi ZM.
    Catheter Cardiovasc Interv; 1999 May 15; 47(1):36-8. PubMed ID: 10385155
    [Abstract] [Full Text] [Related]

  • 5. Different transcatheter strategies for aortic coarctation associated with patent ductus arteriosus.
    Singhi AK, Sivakumar K.
    Indian Heart J; 2012 May 15; 64(4):423-6. PubMed ID: 22929832
    [Abstract] [Full Text] [Related]

  • 6. Interventional cardiac catheterization therapy for combined coarctation of the aorta and patent ductus arteriosus: successful outcome in two infants.
    Geggel RL, Hijazi ZM, Rhodes J.
    Cathet Cardiovasc Diagn; 1996 May 15; 38(1):67-70; discussion 71. PubMed ID: 8722861
    [Abstract] [Full Text] [Related]

  • 7. Development of aortic coarctation following device closure of patent ductus arteriosus.
    Doshi AR, Rao PS.
    J Invasive Cardiol; 2013 Sep 15; 25(9):464-7. PubMed ID: 23995721
    [Abstract] [Full Text] [Related]

  • 8. False aneurysm and mediastinal hematoma: complications of simultaneous transcatheter therapy for coarctation of the aorta and patent ductus arteriosus in an infant.
    Liang CD, Ko SF, Tiao MM.
    J Invasive Cardiol; 2001 Oct 15; 13(10):710-2. PubMed ID: 11581516
    [Abstract] [Full Text] [Related]

  • 9. Successful transcatheter closure of patent arterial duct six years after balloon dilatation of coarctation of the aorta.
    Galal O, al-Fadley F, Wilson N.
    Int J Cardiol; 1992 Apr 15; 35(1):123-5. PubMed ID: 1563870
    [Abstract] [Full Text] [Related]

  • 10. Interventional cardiac catheterization for the coarctation of the aortic arch and patent ductus arteriosus in a 3-day-old neonate with the Holt-Oram syndrome.
    Lee ML, Tsao LY, Wang YM.
    Int J Cardiol; 2005 Jun 08; 101(3):503-5. PubMed ID: 15907425
    [No Abstract] [Full Text] [Related]

  • 11. Transcatheter occlusion of the patent ductus arteriosus in the presence of mild isthmal hypoplasia.
    Nykanen DG, Hayes AM, Benson LN, Freedom RM.
    Cathet Cardiovasc Diagn; 1993 Aug 08; 29(4):273-6. PubMed ID: 8221845
    [Abstract] [Full Text] [Related]

  • 12. Simultaneous treatment of native coarctation of the aorta combined with patent ductus arteriosus using a covered stent.
    Sadiq M, Malick NH, Qureshi SA.
    Catheter Cardiovasc Interv; 2003 Jul 08; 59(3):387-90. PubMed ID: 12822166
    [Abstract] [Full Text] [Related]

  • 13. Stent implantation for coarctation of aorta caused by a Rashkind patent ductus arteriosus umbrella.
    Beck A, Birk E, Blieden LC, Bruckheimer E.
    Catheter Cardiovasc Interv; 2004 Sep 08; 63(1):80-2. PubMed ID: 15343573
    [Abstract] [Full Text] [Related]

  • 14. Prostaglandin Infusion in Neonate With Severe Coarctation of the Aorta With Closed Ductus Arteriosus-A Case Report and Review of the Literature.
    Bansal N, Balakrishnan PL, Aggarwal S.
    World J Pediatr Congenit Heart Surg; 2020 Jul 08; 11(4):NP239-NP243. PubMed ID: 31010402
    [Abstract] [Full Text] [Related]

  • 15. Coarctation of the aorta following coil occlusion of a patent ductus arteriosus.
    Moore JD, Shim D, Mendelsohn AM, Kimball TR.
    Cathet Cardiovasc Diagn; 1998 Jan 08; 43(1):60-2. PubMed ID: 9473193
    [Abstract] [Full Text] [Related]

  • 16. Aortic thrombus after coil occlusion of a type E patent ductus arteriosus.
    Villafañe J, Vega-Arrillaga F.
    Tex Heart Inst J; 2002 Jan 08; 29(3):210-2. PubMed ID: 12224726
    [Abstract] [Full Text] [Related]

  • 17. Interventional treatment of critical coarctation of the aorta in an extremely low birth weight preterm neonate.
    Dryzek P, Goreczny S, Kopala M.
    Cardiol Young; 2012 Aug 08; 22(4):475-7. PubMed ID: 22182423
    [Abstract] [Full Text] [Related]

  • 18. Late manifestation coarctation of the aorta in a premature infant 4-month post-percutaneous device closure of a patent ductus arteriosus.
    Serrano RM, Rodefeld MD, Alexy R.
    Cardiol Young; 2019 Dec 08; 29(12):1556-1558. PubMed ID: 31760959
    [Abstract] [Full Text] [Related]

  • 19. Coil occlusion of patent ductus arteriosus associated with right aortic arch.
    Rao PS, Wagman AJ, Chen SC.
    Catheter Cardiovasc Interv; 2001 Jan 08; 52(1):79-82. PubMed ID: 11146529
    [Abstract] [Full Text] [Related]

  • 20. Ductus-dependent aortic coarctation with a left-to-right shunt through the ductus: report of one case.
    Cheng CF, Wu MH, Wang JK.
    Int J Cardiol; 1995 May 08; 49(3):209-12; discussion 212-3. PubMed ID: 7649666
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 10.