These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


432 related items for PubMed ID: 9112467

  • 21. Verification of source and collimator configuration for Gamma Knife Perfexion using panoramic imaging.
    Cho YB, van Prooijen M, Jaffray DA, Islam MK.
    Med Phys; 2010 Mar; 37(3):1325-31. PubMed ID: 20384269
    [Abstract] [Full Text] [Related]

  • 22. Commissioning of a micro multi-leaf collimator and planning system for stereotactic radiosurgery.
    Cosgrove VP, Jahn U, Pfaender M, Bauer S, Budach V, Wurm RE.
    Radiother Oncol; 1999 Mar; 50(3):325-36. PubMed ID: 10392819
    [Abstract] [Full Text] [Related]

  • 23. Feasibility of single-isocenter, multi-arc non-coplanar volumetric modulated arc therapy for multiple brain tumors using a linear accelerator with a 160-leaf multileaf collimator: a phantom study.
    Iwai Y, Ozawa S, Ageishi T, Pellegrini R, Yoda K.
    J Radiat Res; 2014 Sep; 55(5):1015-20. PubMed ID: 24944266
    [Abstract] [Full Text] [Related]

  • 24. [Quality control (QC) of CT on rail system (FOCAL Unit) with a micro-multi leaf collimator (mMLC) using new GafChromic film for stereotactic radiotherapy].
    Oita M, Takegawa Y, Yagi H, Ikushima H, Osaki K, Furutani S, Sasaki M, Tominaga M, Nishimoto Y, Nishitani H.
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2006 May 20; 62(5):711-3. PubMed ID: 16770852
    [Abstract] [Full Text] [Related]

  • 25. Dynamic arc radiosurgery and radiotherapy: commissioning and verification of dose distributions.
    Grebe G, Pfaender M, Roll M, Luedemann L, Wurm RE.
    Int J Radiat Oncol Biol Phys; 2001 Apr 01; 49(5):1451-60. PubMed ID: 11286853
    [Abstract] [Full Text] [Related]

  • 26. Stereotactic IMRT for prostate cancer: dosimetric impact of multileaf collimator leaf width in the treatment of prostate cancer with IMRT.
    Wang L, Movsas B, Jacob R, Fourkal E, Chen L, Price R, Feigenberg S, Konski A, Pollack A, Ma C.
    J Appl Clin Med Phys; 2004 Apr 01; 5(2):29-41. PubMed ID: 15738911
    [Abstract] [Full Text] [Related]

  • 27. A comparison of dose distributions of proton and photon beams in stereotactic conformal radiotherapy of brain lesions.
    Baumert BG, Lomax AJ, Miltchev V, Davis JB.
    Int J Radiat Oncol Biol Phys; 2001 Apr 01; 49(5):1439-49. PubMed ID: 11286852
    [Abstract] [Full Text] [Related]

  • 28. Impact of collimator leaf width and treatment technique on stereotactic radiosurgery and radiotherapy plans for intra- and extracranial lesions.
    Wu QJ, Wang Z, Kirkpatrick JP, Chang Z, Meyer JJ, Lu M, Huntzinger C, Yin FF.
    Radiat Oncol; 2009 Jan 21; 4():3. PubMed ID: 19159471
    [Abstract] [Full Text] [Related]

  • 29. Killing two birds with one stone: a dosimetric study of dual target radiosurgery using a single isocenter.
    Roberge D, Ruo R, Souhami L.
    Technol Cancer Res Treat; 2006 Dec 21; 5(6):613-7. PubMed ID: 17121438
    [Abstract] [Full Text] [Related]

  • 30. Dosimetric feasibility of brain stereotactic radiosurgery with a 0.35 T MRI-guided linac and comparison vs a C-arm-mounted linac.
    Slagowski JM, Redler G, Malin MJ, Cammin J, Lobb EC, Lee BH, Sethi A, Roeske JC, Flores-Martinez E, Stevens T, Yenice KM, Green O, Mutic S, Aydogan B.
    Med Phys; 2020 Nov 21; 47(11):5455-5466. PubMed ID: 32996591
    [Abstract] [Full Text] [Related]

  • 31. SU-E-T-645: Treatment of Multiple Brain Metastases Using Stereotactic Radiosurgery with Single-Isocenter Volumetric Modulated Arc Therapy: Comparison with Conventional Dynamic Conformal Arc and Static Beam Stereotactic Radiosurgery.
    Huang C, Ren L, Kirkpatrick J, Wang Z.
    Med Phys; 2012 Jun 21; 39(6Part20):3854. PubMed ID: 28517544
    [Abstract] [Full Text] [Related]

  • 32. Comparison of a micro-multileaf collimator with a 5-mm-leaf-width collimator for intracranial stereotactic radiotherapy.
    Monk JE, Perks JR, Doughty D, Plowman PN.
    Int J Radiat Oncol Biol Phys; 2003 Dec 01; 57(5):1443-9. PubMed ID: 14630284
    [Abstract] [Full Text] [Related]

  • 33. Study on dosimetric parameters for stereotactic radiosurgery and intensity-modulated radiotherapy.
    Sankaranarayanan V, Ganesan S, Oommen S, Padmanaban TK, Stumpf J, Ayyangar KM.
    Med Dosim; 2003 Dec 01; 28(2):85-90. PubMed ID: 12804705
    [Abstract] [Full Text] [Related]

  • 34. Comparison of radiation dose spillage from the Gamma Knife Perfexion with that from volumetric modulated arc radiosurgery during treatment of multiple brain metastases in a single fraction.
    McDonald D, Schuler J, Takacs I, Peng J, Jenrette J, Vanek K.
    J Neurosurg; 2014 Dec 01; 121 Suppl():51-9. PubMed ID: 25434937
    [Abstract] [Full Text] [Related]

  • 35. Treatment planning for stereotactic radiosurgery of intra-cranial lesions.
    Kooy HM, Nedzi LA, Loeffler JS, Alexander E, Cheng CW, Mannarino EG, Holupka EJ, Siddon RL.
    Int J Radiat Oncol Biol Phys; 1991 Aug 01; 21(3):683-93. PubMed ID: 1907960
    [Abstract] [Full Text] [Related]

  • 36. Monte Carlo modeling of the ModuLeaf miniature MLC for small field dosimetry and quality assurance of the clinical treatment planning system.
    Crop F, Reynaert N, Pittomvils G, Paelinck L, De Gersem W, De Wagter C, Vakaet L, De Neve W, Thierens H.
    Phys Med Biol; 2007 Jun 07; 52(11):3275-90. PubMed ID: 17505102
    [Abstract] [Full Text] [Related]

  • 37. Characterization of a novel 3D printed patient specific phantom for quality assurance in cranial stereotactic radiosurgery applications.
    Makris DN, Pappas EP, Zoros E, Papanikolaou N, Saenz DL, Kalaitzakis G, Zourari K, Efstathopoulos E, Maris TG, Pappas E.
    Phys Med Biol; 2019 May 10; 64(10):105009. PubMed ID: 30965289
    [Abstract] [Full Text] [Related]

  • 38. Single isocenter treatment planning for homogeneous dose delivery to nonspherical targets in multiarc linear accelerator radiosurgery.
    Luxton G, Jozsef G.
    Int J Radiat Oncol Biol Phys; 1995 Feb 01; 31(3):635-43. PubMed ID: 7852130
    [Abstract] [Full Text] [Related]

  • 39. Impact of a micromultileaf collimator on stereotactic radiotherapy of uveal melanoma.
    Georg D, Dieckmann K, Bogner J, Zehetmayer M, Pötter R.
    Int J Radiat Oncol Biol Phys; 2003 Mar 15; 55(4):881-91. PubMed ID: 12605965
    [Abstract] [Full Text] [Related]

  • 40. Radiosurgery of small skull-base lesions. No advantage for intensity-modulated stereotactic radiosurgery versus conformal arc technique.
    Ernst-Stecken A, Lambrecht U, Ganslandt O, Mueller R, Fahlbusch R, Sauer R, Grabenbauer G.
    Strahlenther Onkol; 2005 May 15; 181(5):336-44. PubMed ID: 15900431
    [Abstract] [Full Text] [Related]


    Page: [Previous] [Next] [New Search]
    of 22.