These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
258 related items for PubMed ID: 9225193
41. Gated technetium-99m sestamibi for simultaneous assessment of stress myocardial perfusion, postexercise regional ventricular function and myocardial viability. Correlation with echocardiography and rest thallium-201 scintigraphy. Chua T, Kiat H, Germano G, Maurer G, van Train K, Friedman J, Berman D. J Am Coll Cardiol; 1994 Apr; 23(5):1107-14. PubMed ID: 8144776 [Abstract] [Full Text] [Related]
42. Prognostic implications of a normal stress technetium-99m-tetrofosmin myocardial perfusion study in patients with a healed myocardial infarct and/or previous coronary revascularization. Schinkel AF, Elhendy A, Bax JJ, van Domburg RT, Huurman A, Valkema R, Biagini E, Rizzello V, Feringa HH, Krenning EP, Simoons ML, Poldermans D. Am J Cardiol; 2006 Jan 01; 97(1):1-6. PubMed ID: 16377272 [Abstract] [Full Text] [Related]
43. Prognostic value and quality of life in patients with normal rest thallium-201/stress technetium 99m-tetrofosmin dual-isotope myocardial SPECT. Groutars RG, Verzijlbergen JF, Muller AJ, Ascoop CA, Tiel-van Buul MM, Zwinderman AH, van Hemel NM, van der Wall EE. J Nucl Cardiol; 2000 Jan 01; 7(4):333-41. PubMed ID: 10958275 [Abstract] [Full Text] [Related]
44. Correlation of abnormal response of left ventricular ejection fraction after exercise and left ventricular cavity-to-myocardium count ratio of technetium-99m-tetrofosmin single photon emission computed tomography in patients with coronary artery disease. Ding HJ, Lin CC, Wang JJ, Ho ST, Kao A. Jpn Heart J; 2002 Sep 01; 43(5):505-14. PubMed ID: 12452308 [Abstract] [Full Text] [Related]
46. [Quantitative assessment of myocardial viability following coronary artery bypass grafting using exercise thallium-201 myocardial single photon emission computed tomography and left ventricular regional wall motion]. Yamamoto N, Kazui T, Okawa Y, Komatsu K, Araki E, Tanaka A, Tanaka T, Komatsu S, Kubota M. Nihon Kyobu Geka Gakkai Zasshi; 1989 Dec 01; 37(12):2468-76. PubMed ID: 2625558 [Abstract] [Full Text] [Related]
47. [Improved detection of fill-in using sublingual nitroglycerin in technetium-99m tetrofosmin exercise/rest single photon emission computed tomography one day protocol for old myocardial infarction]. Miyanaga H, Kunieda Y, Oguni A, Kamitani T, Kawasaki S, Takahashi T. J Cardiol; 1999 Mar 01; 33(3):135-43. PubMed ID: 10225193 [Abstract] [Full Text] [Related]
48. Technetium-99m-tetrofosmin imaging with incremental nitroglycerin infusion to detect severely ischaemic but viable myocardium: a comparative study with thallium-201. Kula M, Tutuş A, Unal S, Topsakal R, Ergin A. Nucl Med Commun; 2003 Sep 01; 24(9):987-94. PubMed ID: 12960598 [Abstract] [Full Text] [Related]
49. Tc-99m tetrofosmin myocardial perfusion SPECT after dipyridamole combined with low-level exercise in the diagnosis of coronary artery disease. Fukuzawa S, Ozawa S, Inagaki M, Inoue T, Morooka S, Sugioka J. Ann Nucl Med; 1996 May 01; 10(2):231-5. PubMed ID: 8800453 [Abstract] [Full Text] [Related]
53. A new method to evaluate ischemic heart disease: combined use of rest thallium-201 myocardial SPECT and Tc-99m exercise tetrofosmin first pass and myocardial SPECT. Kim Y, Goto H, Kobayashi K, Sawada Y, Miyake Y, Fujiwara G, Okada T, Nishimura T. Ann Nucl Med; 1999 Jun 01; 13(3):147-53. PubMed ID: 10435374 [Abstract] [Full Text] [Related]
54. [Evaluation of hemodynamic significance of arteriovenous coronary fistulas: diagnostic integration of coronary angiography and stress/rest myocardial scintigraphy]. Rubini G, Ettorre GC, Sebastiani M, Bovenzi F. Radiol Med; 2000 Dec 01; 100(6):453-8. PubMed ID: 11307506 [Abstract] [Full Text] [Related]
56. The role of 99Tcm-tetrofosmin myocardial perfusion scintigraphy in the assessment of patients with previous myocardial infarction: a comparative study with 201Tl. Burak Z, Akin H, Buket S, Sagcan A, Argon M, Atay Y, Durmaz I, Duman Y. Nucl Med Commun; 1998 Feb 01; 19(2):127-36. PubMed ID: 9548196 [Abstract] [Full Text] [Related]
57. Technetium-99m tetrofosmin rest/stress myocardial SPET with a same-day 2-hour protocol: comparison with coronary angiography. A Spanish-Portuguese multicentre clinical trial. Montz R, Perez-Castejón MJ, Jurado JA, Martín-Comín J, Esplugues E, Salgado L, Ventosa A, Cantinho G, Sá EP, Fonseca AT, Vieira MR. Eur J Nucl Med; 1996 Jun 01; 23(6):639-47. PubMed ID: 8662097 [Abstract] [Full Text] [Related]
58. [Estimation of myocardial viability and clinical significance of reverse redistribution in resting technetium-99m sestamibi myocardial single photon emission computed tomography in patients with acute myocardial infarction]. Itagane H, Otsuka M, Yamagishi H, Suto Y, Kajiwara K, Naruko T, Tojo O, Okumachi F, Haze K. J Cardiol; 1997 Oct 01; 30(4):179-88. PubMed ID: 9365855 [Abstract] [Full Text] [Related]
59. Comparison of electrocardiographic-gated technetium-99m sestamibi single-photon emission computed tomographic imaging and rest-redistribution thallium-201 in the prediction of myocardial viability. Duncan BH, Ahlberg AW, Levine MG, McGill CC, Mann A, White MP, Mather JF, Waters DD, Heller GV. Am J Cardiol; 2000 Mar 15; 85(6):680-4. PubMed ID: 12000040 [Abstract] [Full Text] [Related]