These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


218 related items for PubMed ID: 9339451

  • 1. A method to measure arbitrary k-space trajectories for rapid MR imaging.
    Mason GF, Harshbarger T, Hetherington HP, Zhang Y, Pohost GM, Twieg DB.
    Magn Reson Med; 1997 Sep; 38(3):492-6. PubMed ID: 9339451
    [Abstract] [Full Text] [Related]

  • 2. Inductive measurement and encoding of k-space trajectories in MR raw data.
    Pedersen JO, Hanson CG, Xue R, Hanson LG.
    MAGMA; 2019 Dec; 32(6):655-667. PubMed ID: 31363869
    [Abstract] [Full Text] [Related]

  • 3. Simple method for MR gradient system characterization and k-space trajectory estimation.
    Addy NO, Wu HH, Nishimura DG.
    Magn Reson Med; 2012 Jul; 68(1):120-9. PubMed ID: 22189904
    [Abstract] [Full Text] [Related]

  • 4. K-space trajectory mapping and its application for ultrashort Echo time imaging.
    Latta P, Starčuk Z, Gruwel ML, Weber MH, Tomanek B.
    Magn Reson Imaging; 2017 Feb; 36():68-76. PubMed ID: 27742433
    [Abstract] [Full Text] [Related]

  • 5. Simple correction method for k-space trajectory deviations in MRI.
    Duyn JH, Yang Y, Frank JA, van der Veen JW.
    J Magn Reson; 1998 May; 132(1):150-3. PubMed ID: 9615415
    [Abstract] [Full Text] [Related]

  • 6. Estimation of k-space trajectories in spiral MRI.
    Tan H, Meyer CH.
    Magn Reson Med; 2009 Jun; 61(6):1396-404. PubMed ID: 19353671
    [Abstract] [Full Text] [Related]

  • 7. Frequency resolved single-shot MR imaging using stochastic k-space trajectories.
    Scheffler K, Hennig J.
    Magn Reson Med; 1996 Apr; 35(4):569-76. PubMed ID: 8992208
    [Abstract] [Full Text] [Related]

  • 8. Spiral imaging artifact reduction: a comparison of two k-trajectory measurement methods.
    Lechner SM, Sipilä PT, Wiesinger F, Kerr AB, Vogel MW.
    J Magn Reson Imaging; 2009 Jun; 29(6):1485-92. PubMed ID: 19472426
    [Abstract] [Full Text] [Related]

  • 9. Imperfect magnetic field gradients in radial k-space encoding-Quantification, correction, and parameter dependency.
    Moussavi A, Boretius S.
    Magn Reson Med; 2019 Feb; 81(2):962-975. PubMed ID: 30260028
    [Abstract] [Full Text] [Related]

  • 10.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 11. Single-shot 3D GRASE with cylindrical k-space trajectories.
    Ramanna S, Feinberg DA.
    Magn Reson Med; 2008 Oct; 60(4):976-80. PubMed ID: 18816819
    [Abstract] [Full Text] [Related]

  • 12.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 13.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 14. Characterization and correction of system delays and eddy currents for MR imaging with ultrashort echo-time and time-varying gradients.
    Atkinson IC, Lu A, Thulborn KR.
    Magn Reson Med; 2009 Aug; 62(2):532-7. PubMed ID: 19353662
    [Abstract] [Full Text] [Related]

  • 15. Improved UTE-based attenuation correction for cranial PET-MR using dynamic magnetic field monitoring.
    Aitken AP, Giese D, Tsoumpas C, Schleyer P, Kozerke S, Prieto C, Schaeffter T.
    Med Phys; 2014 Jan; 41(1):012302. PubMed ID: 24387523
    [Abstract] [Full Text] [Related]

  • 16.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 17. Non-Cartesian k-space trajectory calculation based on concurrent reading of the gradient amplifiers' output currents.
    Rahmer J, Schmale I, Mazurkewitz P, Lips O, Börnert P.
    Magn Reson Med; 2021 Jun; 85(6):3060-3070. PubMed ID: 33604921
    [Abstract] [Full Text] [Related]

  • 18. A rapid and robust gradient measurement technique using dynamic single-point imaging.
    Jang H, McMillan AB.
    Magn Reson Med; 2017 Sep; 78(3):950-962. PubMed ID: 27699867
    [Abstract] [Full Text] [Related]

  • 19. A simple acquisition strategy to avoid off-resonance blurring in spiral imaging with redundant spiral-in/out k-space trajectories.
    Fielden SW, Meyer CH.
    Magn Reson Med; 2015 Feb; 73(2):704-10. PubMed ID: 24604539
    [Abstract] [Full Text] [Related]

  • 20. Design of a logarithmic k-space spiral trajectory.
    Cline HE, Zong X, Gai N.
    Magn Reson Med; 2001 Dec; 46(6):1130-5. PubMed ID: 11746579
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 11.