These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
148 related items for PubMed ID: 937815
1. Ear oximetry: accuracy and practicability in the assessment of arterial oxygenation. Saunders NA, Powles AC, Rebuck AS. Am Rev Respir Dis; 1976 Jun; 113(6):745-9. PubMed ID: 937815 [Abstract] [Full Text] [Related]
2. The accuracy and response characteristics of a simplified ear oximeter. Chapman KR, D'Urzo A, Rebuck AS. Chest; 1983 Jun; 83(6):860-4. PubMed ID: 6851688 [Abstract] [Full Text] [Related]
4. The accuracy of the Hewlett-Packard 47201A ear oximeter below 50% saturation. Stradling JR. Bull Eur Physiopathol Respir; 1982 Feb; 18(5):791-4. PubMed ID: 6927531 [Abstract] [Full Text] [Related]
5. Simultaneous comparison of three noninvasive oximeters in healthy volunteers. Mendelson Y, Kent JC, Shahnarian A, Welch GW, Giasi RM. Med Instrum; 1987 Jun; 21(3):183-8. PubMed ID: 3614041 [Abstract] [Full Text] [Related]
6. Continuous in vivo measurement of arterial oxygen saturation by oximetry. Flick MR, Block AJ. Heart Lung; 1977 Jun; 6(6):990-3. PubMed ID: 244328 [Abstract] [Full Text] [Related]
7. Accuracy of two ear oximeters at rest and during exercise in pulmonary patients. Ries AL, Farrow JT, Clausen JL. Am Rev Respir Dis; 1985 Sep; 132(3):685-9. PubMed ID: 4037542 [Abstract] [Full Text] [Related]
8. Accuracy sensitivity to carboxyhemoglobin, and speed of response of the Hewlett-Packard 47201A ear oximeter. Douglas NJ, Brash HM, Wraith PK, Calverley PM, Leggett RJ, McElderry L, Flenley DC. Am Rev Respir Dis; 1979 Feb; 119(2):311-3. PubMed ID: 434601 [Abstract] [Full Text] [Related]
10. Reliability of noninvasive oximetry in black subjects during exercise and hypoxia. Zeballos RJ, Weisman IM. Am Rev Respir Dis; 1991 Dec; 144(6):1240-4. PubMed ID: 1741533 [Abstract] [Full Text] [Related]
11. Accuracy of two pulse oximeters at low arterial hemoglobin-oxygen saturation. Carter BG, Carlin JB, Tibballs J, Mead H, Hochmann M, Osborne A. Crit Care Med; 1998 Jun; 26(6):1128-33. PubMed ID: 9635666 [Abstract] [Full Text] [Related]
12. Dynamic in vivo response characteristics of three oximeters: Hewlett-Packard 47201A, Biox III, and Nellcor N-100. West P, George CF, Kryger MH. Sleep; 1987 Jun; 10(3):263-71. PubMed ID: 3629089 [Abstract] [Full Text] [Related]
13. Assessment of two noninvasive monitors of arterial oxygenation in anesthetized man. Knill RL, Clement JL, Kieraszewicz HT, Dodgson BG. Anesth Analg; 1982 Jul; 61(7):582-6. PubMed ID: 7201256 [Abstract] [Full Text] [Related]
14. Calibration of a new ear oximeter in humans during exposure to centrifugation. Besch EL, Baumgardner FW, Burton RR, Gillingham KK, McPherson RF, Leverett SD. J Appl Physiol Respir Environ Exerc Physiol; 1978 Mar; 44(3):483-7. PubMed ID: 632190 [Abstract] [Full Text] [Related]
15. A comparison of a new reflectance oximeter with the Hewlett-Packard ear oximeter. Decker MJ, Dickensheets D, Arnold JL, Cheung PW, Strohl KP. Biomed Instrum Technol; 1990 Mar; 24(2):122-6. PubMed ID: 2322755 [Abstract] [Full Text] [Related]
16. Evaluation of the Datascope ACCUSAT pulse oximeter in healthy adults. Mendelson Y, Kent JC, Shahnarian A, Welch GW, Giasi RM. J Clin Monit; 1988 Jan; 4(1):59-63. PubMed ID: 3339392 [Abstract] [Full Text] [Related]
17. Accuracy of three pulse oximeters during exercise and hypoxemia in patients with cystic fibrosis. Orenstein DM, Curtis SE, Nixon PA, Hartigan ER. Chest; 1993 Oct; 104(4):1187-90. PubMed ID: 8404189 [Abstract] [Full Text] [Related]
18. Factors affecting the performance of 5 cerebral oximeters during hypoxia in healthy volunteers. Bickler PE, Feiner JR, Rollins MD. Anesth Analg; 2013 Oct; 117(4):813-823. PubMed ID: 24023027 [Abstract] [Full Text] [Related]
19. [Accuracy of an the ear oximeter Biox-III and its sensitivity to carboxyhemoglobin in Mexico City]. Pérez-Padilla JR, Bracamonte-Peraza R, Manrique G, Ruiz-Primo ME. Arch Inst Cardiol Mex; 1986 Oct; 56(4):303-7. PubMed ID: 2945522 [Abstract] [Full Text] [Related]
20. The Accuracy of 6 Inexpensive Pulse Oximeters Not Cleared by the Food and Drug Administration: The Possible Global Public Health Implications. Lipnick MS, Feiner JR, Au P, Bernstein M, Bickler PE. Anesth Analg; 2016 Aug; 123(2):338-45. PubMed ID: 27089002 [Abstract] [Full Text] [Related] Page: [Next] [New Search]