These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
178 related items for PubMed ID: 9402204
1. Elimination of eddy current artifacts in diffusion-weighted echo-planar images: the use of bipolar gradients. Alexander AL, Tsuruda JS, Parker DL. Magn Reson Med; 1997 Dec; 38(6):1016-21. PubMed ID: 9402204 [Abstract] [Full Text] [Related]
2. Mapping eddy current induced fields for the correction of diffusion-weighted echo planar images. Horsfield MA. Magn Reson Imaging; 1999 Nov; 17(9):1335-45. PubMed ID: 10576719 [Abstract] [Full Text] [Related]
3. Characterization of and correction for eddy current artifacts in echo planar diffusion imaging. Jezzard P, Barnett AS, Pierpaoli C. Magn Reson Med; 1998 May; 39(5):801-12. PubMed ID: 9581612 [Abstract] [Full Text] [Related]
4. Reduction of eddy-current-induced distortion in diffusion MRI using a twice-refocused spin echo. Reese TG, Heid O, Weisskoff RM, Wedeen VJ. Magn Reson Med; 2003 Jan; 49(1):177-82. PubMed ID: 12509835 [Abstract] [Full Text] [Related]
5. Geometric distortion correction of high-resolution 3 T diffusion tensor brain images. Ardekani S, Sinha U. Magn Reson Med; 2005 Nov; 54(5):1163-71. PubMed ID: 16187289 [Abstract] [Full Text] [Related]
6. Prospective and retrospective high order eddy current mitigation for diffusion weighted echo planar imaging. Xu D, Maier JK, King KF, Collick BD, Wu G, Peters RD, Hinks RS. Magn Reson Med; 2013 Nov; 70(5):1293-305. PubMed ID: 23325564 [Abstract] [Full Text] [Related]
7. Double-spin-echo diffusion weighting with a modified eddy current adjustment. Finsterbusch J. Magn Reson Imaging; 2010 Apr; 28(3):434-40. PubMed ID: 20071120 [Abstract] [Full Text] [Related]
8. Eddy current-induced artifact correction in high b-value ex vivo human brain diffusion MRI with dynamic field monitoring. Ramos-Llordén G, Park DJ, Kirsch JE, Scholz A, Keil B, Maffei C, Lee HH, Bilgic B, Edlow BL, Mekkaoui C, Yendiki A, Witzel T, Huang SY. Magn Reson Med; 2024 Feb; 91(2):541-557. PubMed ID: 37753621 [Abstract] [Full Text] [Related]
9. Echoplanar diffusion tensor imaging of the lower leg musculature using eddy current nulled stimulated echo preparation. Steidle G, Schick F. Magn Reson Med; 2006 Mar; 55(3):541-8. PubMed ID: 16450364 [Abstract] [Full Text] [Related]
10. A hybrid strategy for correcting geometric distortion in echo-planar images. Gelman N, Silavi A, Anazodo U. Magn Reson Imaging; 2014 Jun; 32(5):590-3. PubMed ID: 24650682 [Abstract] [Full Text] [Related]
11. High-resolution diffusion imaging using a radial turbo-spin-echo sequence: implementation, eddy current compensation, and self-navigation. Seifert MH, Jakob PM, Jellus V, Haase A, Hillenbrand C. J Magn Reson; 2000 Jun; 144(2):243-54. PubMed ID: 10828192 [Abstract] [Full Text] [Related]
12. Characterization and correction of time-varying eddy currents for diffusion MRI. Valsamis JJ, Dubovan PI, Baron CA. Magn Reson Med; 2022 May; 87(5):2209-2223. PubMed ID: 34894640 [Abstract] [Full Text] [Related]
13. Accelerated point spread function mapping using signal modeling for accurate echo-planar imaging geometric distortion correction. Dragonu I, Lange T, Baxan N, Snyder J, Hennig J, Zaitsev M. Magn Reson Med; 2013 Jun; 69(6):1650-6. PubMed ID: 22807105 [Abstract] [Full Text] [Related]
14. Correction of high-order eddy current induced geometric distortion in diffusion-weighted echo-planar images. Shen Y, Larkman DJ, Counsell S, Pu IM, Edwards D, Hajnal JV. Magn Reson Med; 2004 Nov; 52(5):1184-9. PubMed ID: 15508159 [Abstract] [Full Text] [Related]
15. Characterization and correction of diffusion gradient-induced eddy currents in second-order motion-compensated echo-planar and spiral cardiac DTI. van Gorkum RJH, Guenthner C, Koethe A, Stoeck CT, Kozerke S. Magn Reson Med; 2022 Dec; 88(6):2378-2394. PubMed ID: 35916545 [Abstract] [Full Text] [Related]
16. Correction of eddy-current distortions in diffusion tensor images using the known directions and strengths of diffusion gradients. Zhuang J, Hrabe J, Kangarlu A, Xu D, Bansal R, Branch CA, Peterson BS. J Magn Reson Imaging; 2006 Nov; 24(5):1188-93. PubMed ID: 17024663 [Abstract] [Full Text] [Related]
17. PSF mapping-based correction of eddy-current-induced distortions in diffusion-weighted echo-planar imaging. In MH, Posnansky O, Speck O. Magn Reson Med; 2016 May; 75(5):2055-63. PubMed ID: 26096666 [Abstract] [Full Text] [Related]
18. Evaluation of eddy current distortion and field inhomogeneity distortion corrections in MR diffusion imaging using log-demons DIR method. Arsenault T, Yin FF, Chino J, Craciunescu O, Chang JZ. Phys Med Biol; 2021 Jan 29; 66(3):035021. PubMed ID: 33202395 [Abstract] [Full Text] [Related]
19. Correction for eddy current induced Bo shifts in diffusion-weighted echo-planar imaging. Calamante F, Porter DA, Gadian DG, Connelly A. Magn Reson Med; 1999 Jan 29; 41(1):95-102. PubMed ID: 10025616 [Abstract] [Full Text] [Related]
20. Eddy-current compensated diffusion weighting with a single refocusing RF pulse. Finsterbusch J. Magn Reson Med; 2009 Mar 29; 61(3):748-54. PubMed ID: 19132755 [Abstract] [Full Text] [Related] Page: [Next] [New Search]