These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
178 related items for PubMed ID: 9402204
41. Eddy current nulled constrained optimization of isotropic diffusion encoding gradient waveforms. Yang G, McNab JA. Magn Reson Med; 2019 Mar; 81(3):1818-1832. PubMed ID: 30368913 [Abstract] [Full Text] [Related]
42. Isotropic diffusion-weighted and spiral-navigated interleaved EPI for routine imaging of acute stroke. Butts K, Pauly J, de Crespigny A, Moseley M. Magn Reson Med; 1997 Nov; 38(5):741-9. PubMed ID: 9358448 [Abstract] [Full Text] [Related]
43. Performance of single spin-echo and doubly refocused diffusion-weighted sequences in the presence of eddy current fields with multiple components. Nunes RG, Drobnjak I, Clare S, Jezzard P, Jenkinson M. Magn Reson Imaging; 2011 Jun; 29(5):659-67. PubMed ID: 21531107 [Abstract] [Full Text] [Related]
44. Readout-segmented echo-planar imaging in the evaluation of sinonasal lesions: A comprehensive comparison of image quality in single-shot echo-planar imaging. Zhao M, Liu Z, Sha Y, Wang S, Ye X, Pan Y, Wang S. Magn Reson Imaging; 2016 Feb; 34(2):166-72. PubMed ID: 26541548 [Abstract] [Full Text] [Related]
45. A feasible study on using multiplexed sensitivity-encoding to reduce geometric distortion in diffusion-weighted echo planar imaging. Chen X, Zhang Y, Cao Y, Sun R, Huang P, Xu Y, Wang W, Feng Q, Xiao J, Yi J, Li Y, Dai J. Magn Reson Imaging; 2018 Dec; 54():153-159. PubMed ID: 30171998 [Abstract] [Full Text] [Related]
46. Application of k-space energy spectrum analysis to susceptibility field mapping and distortion correction in gradient-echo EPI. Chen NK, Oshio K, Panych LP. Neuroimage; 2006 Jun; 31(2):609-22. PubMed ID: 16480898 [Abstract] [Full Text] [Related]
47. Correction for distortion of echo-planar images used to calculate the apparent diffusion coefficient. Haselgrove JC, Moore JR. Magn Reson Med; 1996 Dec; 36(6):960-4. PubMed ID: 8946363 [Abstract] [Full Text] [Related]
48. Double half RF pulses for reduced sensitivity to eddy currents in UTE imaging. Josan S, Pauly JM, Daniel BL, Pauly KB. Magn Reson Med; 2009 May; 61(5):1083-9. PubMed ID: 19235919 [Abstract] [Full Text] [Related]
49. Readout-segmented echo-planar imaging for diffusion-weighted imaging in the pelvis at 3T-A feasibility study. Thian YL, Xie W, Porter DA, Weileng Ang B. Acad Radiol; 2014 Apr; 21(4):531-7. PubMed ID: 24594423 [Abstract] [Full Text] [Related]
50. The effect of residual Nyquist ghost in quantitative echo-planar diffusion imaging. Porter DA, Calamante F, Gadian DG, Connelly A. Magn Reson Med; 1999 Aug; 42(2):385-92. PubMed ID: 10440964 [Abstract] [Full Text] [Related]
51. Eddy current correction in diffusion-weighted imaging using pairs of images acquired with opposite diffusion gradient polarity. Bodammer N, Kaufmann J, Kanowski M, Tempelmann C. Magn Reson Med; 2004 Jan; 51(1):188-93. PubMed ID: 14705060 [Abstract] [Full Text] [Related]
52. Echoplanar MR imaging for ultrafast detection of brain lesions. Patel MR, Siewert B, Klufas R, Yousuf N, Edelman RR, Warach S. AJR Am J Roentgenol; 1999 Aug; 173(2):479-85. PubMed ID: 10430158 [Abstract] [Full Text] [Related]
53. Simultaneous acquisition of gradient-echo and asymmetric spin-echo for single-shot z-shim: Z-SAGA. Heberlein KA, Hu X. Magn Reson Med; 2004 Jan; 51(1):212-6. PubMed ID: 14705064 [Abstract] [Full Text] [Related]
54. New approach for correcting distortions in echo planar imaging. Zeng H, Gatenby JC, Zhao Y, Gore JC. Magn Reson Med; 2004 Dec; 52(6):1373-8. PubMed ID: 15562492 [Abstract] [Full Text] [Related]
55. Correction for direction-dependent distortions in diffusion tensor imaging using matched magnetic field maps. Chen B, Guo H, Song AW. Neuroimage; 2006 Mar; 30(1):121-9. PubMed ID: 16242966 [Abstract] [Full Text] [Related]
56. Correction of concomitant magnetic field-induced image artifacts in nonaxial echo-planar imaging. Du YP, Joe Zhou X, Bernstein MA. Magn Reson Med; 2002 Sep; 48(3):509-15. PubMed ID: 12210916 [Abstract] [Full Text] [Related]
57. Optimization of diffusion-weighted single-refocused spin-echo EPI by reducing eddy-current artifacts and shortening the echo time. Shrestha M, Hok P, Nöth U, Lienerth B, Deichmann R. MAGMA; 2018 Oct; 31(5):585-597. PubMed ID: 29603048 [Abstract] [Full Text] [Related]
58. Point spread function mapping with parallel imaging techniques and high acceleration factors: fast, robust, and flexible method for echo-planar imaging distortion correction. Zaitsev M, Hennig J, Speck O. Magn Reson Med; 2004 Nov; 52(5):1156-66. PubMed ID: 15508146 [Abstract] [Full Text] [Related]
59. Reduction of magnetic field inhomogeneity artifacts in echo planar imaging with SENSE and GESEPI at high field. Yang QX, Wang J, Smith MB, Meadowcroft M, Sun X, Eslinger PJ, Golay X. Magn Reson Med; 2004 Dec; 52(6):1418-23. PubMed ID: 15562468 [Abstract] [Full Text] [Related]
60. Stimulated echo induced misestimates on diffusion tensor indices and its remedy. Chuang TC, Wu MT, Huang TY, Lin YR, Tsai SY, Chang HC, Chung HW. J Magn Reson Imaging; 2010 Jun; 31(6):1522-9. PubMed ID: 20512910 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]