These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. Spinal sealant system provides better intraoperative watertight closure than standard of care during spinal surgery: a prospective, multicenter, randomized controlled study. Wright NM, Park J, Tew JM, Kim KD, Shaffrey ME, Cheng J, Choudhri H, Krishnaney AA, Graham RS, Mendel E, Simmons N. Spine (Phila Pa 1976); 2015 Apr 15; 40(8):505-13. PubMed ID: 25646746 [Abstract] [Full Text] [Related]
11. Safety and efficacy of a novel polyethylene glycol hydrogel sealant for watertight dural repair. Cosgrove GR, Delashaw JB, Grotenhuis JA, Tew JM, Van Loveren H, Spetzler RF, Payner T, Rosseau G, Shaffrey ME, Hopkins LN, Byrne R, Norbash A. J Neurosurg; 2007 Jan 15; 106(1):52-8. PubMed ID: 17236487 [Abstract] [Full Text] [Related]
12. DuraSeal magnetic resonance and computed tomography imaging: evaluation in a canine craniotomy model. Kacher DF, Frerichs K, Pettit J, Campbell PK, Meunch T, Norbash AM. Neurosurgery; 2006 Feb 15; 58(1 Suppl):ONS140-7; discussion ONS140-7. PubMed ID: 16543872 [Abstract] [Full Text] [Related]
13. The safety and effectiveness of a dural sealant system for use with nonautologous duraplasty materials. Weinstein JS, Liu KC, Delashaw JB, Burchiel KJ, van Loveren HR, Vale FL, Agazzi S, Greenberg MS, Smith DA, Tew J. J Neurosurg; 2010 Feb 15; 112(2):428-33. PubMed ID: 19645538 [Abstract] [Full Text] [Related]
14. A Pivotal Randomized Clinical Trial Evaluating the Safety and Effectiveness of a Novel Hydrogel Dural Sealant as an Adjunct to Dural Repair. Strong MJ, West GA, Woo H, Couture DE, Wilson JA, Munoz LF, Rosen CL, Greenlee JD, van Loveren HR, Iantosca M, Baird CJ, Smith M, McGirt M, Parish J, Asher AL. Oper Neurosurg (Hagerstown); 2017 Apr 01; 13(2):204-212. PubMed ID: 28927211 [Abstract] [Full Text] [Related]
15. Evaluation of fibrin sealants for central nervous system sealing in the mongrel dog durotomy model. Hutchinson RW, Mendenhall V, Abutin RM, Muench T, Hart J. Neurosurgery; 2011 Oct 01; 69(4):921-8; discussion 929. PubMed ID: 21552173 [Abstract] [Full Text] [Related]
16. Biocompatibility evaluation of dura mater substitutes in an animal model. Barbolt TA, Odin M, Léger M, Kangas L, Hoiste J, Liu SH. Neurol Res; 2001 Dec 01; 23(8):813-20. PubMed ID: 11760872 [Abstract] [Full Text] [Related]
17. Comparative study of fibrin and chemical synthetic sealant on dural regeneration and brain damage. Ito K, Horiuchi T, Oyanagi K, Nomiyama T, Hongo K. J Neurosurg Spine; 2013 Dec 01; 19(6):736-43. PubMed ID: 24074508 [Abstract] [Full Text] [Related]
18. Delayed cerebrospinal fluid leak after watertight dural closure with a polyethylene glycol hydrogel dural sealant in posterior fossa surgery: case report. Jito J, Nitta N, Nozaki K. Neurol Med Chir (Tokyo); 2014 Dec 01; 54(8):634-9. PubMed ID: 24305019 [Abstract] [Full Text] [Related]
19. The use of a novel perfusion-based cadaveric simulation model with cerebrospinal fluid reconstitution comparing dural repair techniques: a pilot study. Bakhsheshian J, Strickland BA, Patel NN, Jakoi AM, Minneti M, Zada G, Acosta FL, Hsieh PC, Wang JC, Liu JC, Pham MH. Spine J; 2017 Sep 01; 17(9):1335-1341. PubMed ID: 28412565 [Abstract] [Full Text] [Related]