These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
139 related items for PubMed ID: 9502139
1. Long-term durability and patient functional status of the Carpentier-Edwards Perimount pericardial bioprosthesis in the aortic position. Frater RW, Furlong P, Cosgrove DM, Okies JE, Colburn LQ, Katz AS, Lowe NL, Ryba EA. J Heart Valve Dis; 1998 Jan; 7(1):48-53. PubMed ID: 9502139 [Abstract] [Full Text] [Related]
2. Twelve-year experience with Carpentier-Edwards PERIMOUNT pericardial valve in the mitral position: a multicenter study. Marchand M, Aupart M, Norton R, Goldsmith IR, Pelletier C, Pellerin M, Dubiel T, Daenen W, Casselman F, Holden M, David TE, Ryba EA. J Heart Valve Dis; 1998 May; 7(3):292-8. PubMed ID: 9651842 [Abstract] [Full Text] [Related]
3. Twelve-year experience with the 19 mm Carpentier-Edwards pericardial aortic valve. Nakajima H, Aupart MR, Neville PH, Sirinelli AL, Meurisse YA, Marchand MA. J Heart Valve Dis; 1998 Sep; 7(5):534-9. PubMed ID: 9793853 [Abstract] [Full Text] [Related]
4. Seventeen-year clinical results of 1,037 Mitroflow pericardial heart valve prostheses in the aortic position. Yankah CA, Schubel J, Buz S, Siniawski H, Hetzer R. J Heart Valve Dis; 2005 Mar; 14(2):172-9; discussion 179-80. PubMed ID: 15792176 [Abstract] [Full Text] [Related]
6. Simultaneous aortic and mitral valve replacement: predictors of adverse outcome. Kuwaki K, Tsukamoto M, Komatsu K, Morishita K, Sakata J, Abe T. J Heart Valve Dis; 2003 Mar; 12(2):169-76. PubMed ID: 12701788 [Abstract] [Full Text] [Related]
7. Intermediate follow up of the TEKNA bileaflet valve. Seybold-Epting W, Limet R, Scheld H, Frank G, Hannekum A, David M, Tatou E, Wolner E, Loisance D, Kassal H, Ryba EA. J Heart Valve Dis; 1998 Mar; 7(2):219-24. PubMed ID: 9587865 [Abstract] [Full Text] [Related]
8. Experience with low-dose aspirin as thromboprophylaxis for the Tissuemed porcine aortic bioprosthesis: a survey of five years' experience. Goldsmith I, Lip GY, Mukundan S, Rosin MD. J Heart Valve Dis; 1998 Sep; 7(5):574-9. PubMed ID: 9793859 [Abstract] [Full Text] [Related]
9. Four years' experience with the Edwards-Tekna bileaflet valve prosthesis. Calkavur T, Yagdi T, Apaydin A, Islamoglu F, Posacioglu H, Durmaz I, Ozbaran M. J Heart Valve Dis; 2002 Mar; 11(2):263-9. PubMed ID: 12000170 [Abstract] [Full Text] [Related]
10. The Mosaic bioprosthesis in the aortic position at five years. Eichinger W, Günzinger R, Botzenhardt F, Simmerl D, Gansera B, Kemkes BM. J Heart Valve Dis; 2000 Sep; 9(5):653-60. PubMed ID: 11041180 [Abstract] [Full Text] [Related]
11. The Stentless Cryo-Life O'Brien porcine aortic valve at 10 years. Hvass U, Baron F, Elsebaey A, Nguyen D, Flecher E. J Heart Valve Dis; 2004 Nov; 13(6):977-83; discussion 983. PubMed ID: 15597593 [Abstract] [Full Text] [Related]
13. Medtronic mosaic porcine bioprosthesis: investigational center experience to six years. Jamieson WR, Fradet GJ, MacNab JS, Burr LH, Stanford EA, Janusz MT, Abel JG, Germann E, Cheung A. J Heart Valve Dis; 2005 Jan; 14(1):54-63. PubMed ID: 15700437 [Abstract] [Full Text] [Related]
14. Mitroflow pericardial valve prosthesis in the aortic position: an analysis of long-term outcome and prognostic factors. Minami K, Boethig D, Mirow N, Kleikamp G, Koertke H, Godehardt E, Koerfer R. J Heart Valve Dis; 2000 Jan; 9(1):112-22. PubMed ID: 10678383 [Abstract] [Full Text] [Related]
15. Clinical experience with the Carpentier-Edwards supra-annular porcine bioprosthesis implanted in the aortic position. Hurle A, Meseguer J, Llamas P, Casillas JA. J Heart Valve Dis; 1998 May; 7(3):331-5. PubMed ID: 9651848 [Abstract] [Full Text] [Related]
16. Fifteen years follow up with the St. Jude Medical Biocor porcine bioprosthesis. Mykén P, Bech-Hanssen O, Phipps B, Caidahl K. J Heart Valve Dis; 2000 May; 9(3):415-22. PubMed ID: 10888100 [Abstract] [Full Text] [Related]
17. Performance of the Carpentier-Edwards SAV and Hancock-II porcine bioprostheses in aortic valve replacement. Jamieson WR, David TE, Feindel CM, Miyagishima RT, Germann E. J Heart Valve Dis; 2002 May; 11(3):424-30. PubMed ID: 12056738 [Abstract] [Full Text] [Related]
18. Carpentier-Edwards supra-annular bioprosthesis in the aortic position. Has altered design affected performance? Wilson ES, Jamieson MP. J Heart Valve Dis; 1996 Jan; 5(1):40-4. PubMed ID: 8834724 [Abstract] [Full Text] [Related]
19. Long-term outcome of the MitroFlow pericardial bioprosthesis in the elderly after aortic valve replacement. Sjögren J, Gudbjartsson T, Thulin LI. J Heart Valve Dis; 2006 Mar; 15(2):197-202. PubMed ID: 16607900 [Abstract] [Full Text] [Related]
20. Clinical evaluation of the carbomedics prosthesis: experience at providence health system in Portland. Minakata K, Wu Y, Zerr KJ, Grunkemeier GL, Handy JR, Ahmad A, Starr A, Furnary AP. J Heart Valve Dis; 2002 Nov; 11(6):844-50. PubMed ID: 12479287 [Abstract] [Full Text] [Related] Page: [Next] [New Search]