These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. [High resolution reconstruction of PET images using the iterative OSEM algorithm]. Doll J, Henze M, Bublitz O, Werling A, Adam LE, Haberkorn U, Semmler W, Brix G. Nuklearmedizin; 2004 Jun; 43(3):72-8. PubMed ID: 15201947 [Abstract] [Full Text] [Related]
3. [Reduction of radiation exposure in PET examinations by data acquisition in the 3D mode]. Brix G, Adam LE, Zaers J, Trojan H, Bellemann ME, Nosske D, Doll J. Nuklearmedizin; 1999 Apr; 38(3):75-9. PubMed ID: 10320992 [Abstract] [Full Text] [Related]
5. [Diagnostic evaluation of the breast using PET: optimization of data acquisition and postprocessing]. Brix G, Henze M, Doll J, Lucht R, Zaers J, Trojan H, Knopp MV, Haberkorn U. Nuklearmedizin; 2000 Apr; 39(3):62-6. PubMed ID: 10834192 [Abstract] [Full Text] [Related]
9. Clinical implications of different image reconstruction parameters for interpretation of whole-body PET studies in cancer patients. Schöder H, Erdi YE, Chao K, Gonen M, Larson SM, Yeung HW. J Nucl Med; 2004 Apr; 45(4):559-66. PubMed ID: 15073250 [Abstract] [Full Text] [Related]
10. Evaluating performance of reconstruction algorithms for 3-D [15O] water PET using subtraction analysis. Liow JS, Zhou L. IEEE Trans Med Imaging; 2000 May; 19(5):522-31. PubMed ID: 11021695 [Abstract] [Full Text] [Related]
11. Quantitative comparison of analytic and iterative reconstruction methods in 2- and 3-dimensional dynamic cardiac 18F-FDG PET. Lubberink M, Boellaard R, van der Weerdt AP, Visser FC, Lammertsma AA. J Nucl Med; 2004 Dec; 45(12):2008-15. PubMed ID: 15585474 [Abstract] [Full Text] [Related]
12. Improved resolution for PET volume imaging through three-dimensional iterative reconstruction. Liow JS, Strother SC, Rehm K, Rottenberg DA. J Nucl Med; 1997 Oct; 38(10):1623-31. PubMed ID: 9379203 [Abstract] [Full Text] [Related]
13. [Investigation of the resolution and count recovery coefficients of a whole-body PET scanner (Shimadzu SET-2400W) in 2D and 3D mode image]. Watanuki S, Fujiwara T, Ishii K, Miyake M, Itoh M, Kitamura K. Kaku Igaku; 2000 Jan; 37(1):35-41. PubMed ID: 10714066 [Abstract] [Full Text] [Related]
17. Fourier rebinning of time-of-flight PET data. Defrise M, Casey ME, Michel C, Conti M. Phys Med Biol; 2005 Jun 21; 50(12):2749-63. PubMed ID: 15930600 [Abstract] [Full Text] [Related]
18. Analytical reconstruction of deconvolved Fourier rebinned PET sinograms. Alessio A, Sauer K, Kinahan P. Phys Med Biol; 2006 Jan 07; 51(1):77-93. PubMed ID: 16357432 [Abstract] [Full Text] [Related]