8. Programmed ventricular stimulation for arrhythmia risk prediction in patients with idiopathic dilated cardiomyopathy and nonsustained ventricular tachycardia. Grimm W, Hoffmann J, Menz V, Luck K, Maisch B. J Am Coll Cardiol; 1998 Sep 06; 32(3):739-45. PubMed ID: 9741521 [Abstract] [Full Text] [Related]
9. Implantable cardioverter defibrillator events in patients with asymptomatic nonsustained ventricular tachycardia: is device implantation justified? Russo AM, Nayak H, Verdino R, Springman J, Gerstenfeld E, Hsia H, Marchlinski FE. Pacing Clin Electrophysiol; 2003 Dec 06; 26(12):2289-95. PubMed ID: 14675014 [Abstract] [Full Text] [Related]
10. Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients: results from the PREPARE (Primary Prevention Parameters Evaluation) study. Wilkoff BL, Williamson BD, Stern RS, Moore SL, Lu F, Lee SW, Birgersdotter-Green UM, Wathen MS, Van Gelder IC, Heubner BM, Brown ML, Holloman KK, PREPARE Study Investigators. J Am Coll Cardiol; 2008 Aug 12; 52(7):541-50. PubMed ID: 18687248 [Abstract] [Full Text] [Related]
12. Predictive value of ventricular arrhythmia inducibility for subsequent ventricular tachycardia or ventricular fibrillation in Multicenter Automatic Defibrillator Implantation Trial (MADIT) II patients. Daubert JP, Zareba W, Hall WJ, Schuger C, Corsello A, Leon AR, Andrews ML, McNitt S, Huang DT, Moss AJ, MADIT II Study Investigators. J Am Coll Cardiol; 2006 Jan 03; 47(1):98-107. PubMed ID: 16386671 [Abstract] [Full Text] [Related]
13. Programming of implantable cardioverter-defibrillators on the basis of the upper limit of vulnerability. Swerdlow CD, Peter CT, Kass RM, Gang ES, Mandel WJ, Hwang C, Martin DJ, Chen PS. Circulation; 1997 Mar 18; 95(6):1497-504. PubMed ID: 9118518 [Abstract] [Full Text] [Related]
14. Results of delivered therapy for VT or VF in patients with third-generation implantable cardioverter defibrillators. Rabinovich R, Muratore C, Iglesias R, Gonzalez M, Serafrica M, Sosa Liprandi A. Pacing Clin Electrophysiol; 1995 Jan 18; 18(1 Pt 2):133-6. PubMed ID: 7724386 [Abstract] [Full Text] [Related]
15. Extravascular Implantable Cardioverter-Defibrillator Sensing and Detection in a Large Global Population. Swerdlow C, Gillberg J, Boersma LVA, Manlucu J, Zhang X, Zhang Y, Hernandez AA, Bhatia V, Murgatroyd F. JACC Clin Electrophysiol; 2024 Aug 18; 10(8):1896-1912. PubMed ID: 38752961 [Abstract] [Full Text] [Related]
16. Ventricular Tachyarrhythmias in Patients With Hypertrophic Cardiomyopathy and Defibrillators: Triggers, Treatment, and Implications. Link MS, Bockstall K, Weinstock J, Alsheikh-Ali AA, Semsarian C, Estes NAM, Spirito P, Haas TS, Rowin EJ, Maron MS, Maron BJ. J Cardiovasc Electrophysiol; 2017 May 18; 28(5):531-537. PubMed ID: 28240435 [Abstract] [Full Text] [Related]
17. High amplitude T-wave alternans precedes spontaneous ventricular tachycardia or fibrillation in ICD electrograms. Swerdlow CD, Zhou X, Voroshilovsky O, Abeyratne A, Gillberg J. Heart Rhythm; 2008 May 18; 5(5):670-6. PubMed ID: 18452868 [Abstract] [Full Text] [Related]
18. Failure to detect life-threatening arrhythmias in ICDs using single-chamber detection criteria. Stroobandt RX, Duytschaever MF, Strisciuglio T, Van Heuverswyn FE, Timmers L, De Pooter J, Knecht S, Vandekerckhove YR, Kucher A, Tavernier RH. Pacing Clin Electrophysiol; 2019 Jun 18; 42(6):583-594. PubMed ID: 30657188 [Abstract] [Full Text] [Related]
19. Ventricular tachycardia during follow-up in patients resuscitated from ventricular fibrillation: experience from stored electrograms of implantable cardioverter-defibrillators. Rüppel R, Schlüter CA, Boczor S, Meinertz T, Schlüter M, Kuck KH, Cappato R. J Am Coll Cardiol; 1998 Nov 15; 32(6):1724-30. PubMed ID: 9822102 [Abstract] [Full Text] [Related]
20. Performance of an ICD algorithm to detect lead noise and reduce inappropriate shocks. Beau S, Greer S, Ellis CR, Keeney J, Asopa S, Arnold E, Fischer A. J Interv Card Electrophysiol; 2016 Mar 15; 45(2):225-32. PubMed ID: 26739482 [Abstract] [Full Text] [Related] Page: [Next] [New Search]