These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


204 related items for PubMed ID: 9651842

  • 1. Twelve-year experience with Carpentier-Edwards PERIMOUNT pericardial valve in the mitral position: a multicenter study.
    Marchand M, Aupart M, Norton R, Goldsmith IR, Pelletier C, Pellerin M, Dubiel T, Daenen W, Casselman F, Holden M, David TE, Ryba EA.
    J Heart Valve Dis; 1998 May; 7(3):292-8. PubMed ID: 9651842
    [Abstract] [Full Text] [Related]

  • 2. Twelve-year experience with the 19 mm Carpentier-Edwards pericardial aortic valve.
    Nakajima H, Aupart MR, Neville PH, Sirinelli AL, Meurisse YA, Marchand MA.
    J Heart Valve Dis; 1998 Sep; 7(5):534-9. PubMed ID: 9793853
    [Abstract] [Full Text] [Related]

  • 3. Long-term durability and patient functional status of the Carpentier-Edwards Perimount pericardial bioprosthesis in the aortic position.
    Frater RW, Furlong P, Cosgrove DM, Okies JE, Colburn LQ, Katz AS, Lowe NL, Ryba EA.
    J Heart Valve Dis; 1998 Jan; 7(1):48-53. PubMed ID: 9502139
    [Abstract] [Full Text] [Related]

  • 4. Perimount pericardial bioprosthesis for aortic calcified stenosis: 18-year experience with 1133 patients.
    Aupart MR, Mirza A, Meurisse YA, Sirinelli AL, Neville PH, Marchand MA.
    J Heart Valve Dis; 2006 Nov; 15(6):768-75; discussion 775-6. PubMed ID: 17152784
    [Abstract] [Full Text] [Related]

  • 5. Aortic and mitral valve replacement with the Carpentier-Edwards pericardial bioprosthesis: 10-year results.
    Murakami T, Eishi K, Nakano S, Kobayashi J, Sasako Y, Isobe F, Kosakai Y, Kito Y, Kawashima Y.
    J Heart Valve Dis; 1996 Jan; 5(1):45-9. PubMed ID: 8834725
    [Abstract] [Full Text] [Related]

  • 6. The Carpentier-Edwards standard porcine bioprosthesis. A first-generation tissue valve with excellent long-term clinical performance.
    Jamieson WR, Allen P, Miyagishima RT, Gerein AN, Munro AI, Burr LH, Tyers GF.
    J Thorac Cardiovasc Surg; 1990 Mar; 99(3):543-61. PubMed ID: 2308373
    [Abstract] [Full Text] [Related]

  • 7. The last generation of pericardial valves in the aortic position: ten-year follow-up in 589 patients.
    Aupart MR, Sirinelli AL, Diemont FF, Meurisse YA, Dreyfus XB, Marchand MA.
    Ann Thorac Surg; 1996 Feb; 61(2):615-20. PubMed ID: 8572776
    [Abstract] [Full Text] [Related]

  • 8. Double valve replacement with the Carpentier-Edwards pericardial valve: 10-year results.
    Aupart MR, Babuty DG, Guesnier L, Meurisse YA, Sirinelli AL, Marchand MA.
    J Heart Valve Dis; 1996 May; 5(3):312-6. PubMed ID: 8793683
    [Abstract] [Full Text] [Related]

  • 9. Clinical experience with the Carpentier-Edwards supra-annular porcine bioprosthesis implanted in the aortic position.
    Hurle A, Meseguer J, Llamas P, Casillas JA.
    J Heart Valve Dis; 1998 May; 7(3):331-5. PubMed ID: 9651848
    [Abstract] [Full Text] [Related]

  • 10. Experience with low-dose aspirin as thromboprophylaxis for the Tissuemed porcine aortic bioprosthesis: a survey of five years' experience.
    Goldsmith I, Lip GY, Mukundan S, Rosin MD.
    J Heart Valve Dis; 1998 Sep; 7(5):574-9. PubMed ID: 9793859
    [Abstract] [Full Text] [Related]

  • 11. Use of the Carpentier-Edwards porcine bioprosthesis: assessment of a patient selection policy.
    Louagie Y, Noirhomme P, Aranguis E, Eucher P, Vanruyssevelt P, Buche M, Dion R, Jaumin P, Schoevaerdts JC, Chalant CH.
    J Thorac Cardiovasc Surg; 1992 Oct; 104(4):1013-24. PubMed ID: 1405658
    [Abstract] [Full Text] [Related]

  • 12. A 25-year experience with Carpentier-Edwards Perimount in the mitral position.
    Ayegnon KG, Aupart M, Bourguignon T, Mirza A, May MA, Marchand M.
    Asian Cardiovasc Thorac Ann; 2011 Feb; 19(1):14-9. PubMed ID: 21357312
    [Abstract] [Full Text] [Related]

  • 13. Porcine versus pericardial bioprostheses: eleven-year follow up of a prospective randomized trial.
    Chaudhry MA, Raco L, Muriithi EW, Bernacca GM, Tolland MM, Wheatley DJ.
    J Heart Valve Dis; 2000 May; 9(3):429-37; discussion 437-8. PubMed ID: 10888102
    [Abstract] [Full Text] [Related]

  • 14. Simultaneous aortic and mitral valve replacement: predictors of adverse outcome.
    Kuwaki K, Tsukamoto M, Komatsu K, Morishita K, Sakata J, Abe T.
    J Heart Valve Dis; 2003 Mar; 12(2):169-76. PubMed ID: 12701788
    [Abstract] [Full Text] [Related]

  • 15. Four years' experience with the Edwards-Tekna bileaflet valve prosthesis.
    Calkavur T, Yagdi T, Apaydin A, Islamoglu F, Posacioglu H, Durmaz I, Ozbaran M.
    J Heart Valve Dis; 2002 Mar; 11(2):263-9. PubMed ID: 12000170
    [Abstract] [Full Text] [Related]

  • 16. Structural durability in Carpentier Edwards Standard bioprosthesis in the mitral position: a 20-year experience.
    Corbineau H, Du Haut Cilly FB, Langanay T, Verhoye JP, Leguerrier A.
    J Heart Valve Dis; 2001 Jul; 10(4):443-8. PubMed ID: 11499587
    [Abstract] [Full Text] [Related]

  • 17. Seventeen-year clinical results of 1,037 Mitroflow pericardial heart valve prostheses in the aortic position.
    Yankah CA, Schubel J, Buz S, Siniawski H, Hetzer R.
    J Heart Valve Dis; 2005 Mar; 14(2):172-9; discussion 179-80. PubMed ID: 15792176
    [Abstract] [Full Text] [Related]

  • 18. Very late outcomes for mitral valve replacement with the Carpentier-Edwards pericardial bioprosthesis: 25-year follow-up of 450 implantations.
    Bourguignon T, Bouquiaux-Stablo AL, Loardi C, Mirza A, Candolfi P, Marchand M, Aupart MR.
    J Thorac Cardiovasc Surg; 2014 Nov; 148(5):2004-2011.e1. PubMed ID: 24667021
    [Abstract] [Full Text] [Related]

  • 19. Aspire porcine bioprosthesis: ten years' experience.
    Hadjinikolaou L, Boehm MC, Ganner C, Kendall SW, Rosin MD, Goldsmith IR, Spyt TJ.
    J Heart Valve Dis; 2005 Jan; 14(1):47-53. PubMed ID: 15700436
    [Abstract] [Full Text] [Related]

  • 20. Lack of durability of the Mitroflow valve does not affect survival.
    Houel R, Le Besnerais P, Soustelle C, Kirsch M, Hillion ML, Loisance D.
    J Heart Valve Dis; 1999 Jul; 8(4):368-74; discussion 374-5. PubMed ID: 10461235
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 11.