These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. A nonlinear spatially variant object-dependent system model for prediction of partial volume effects and scatter in PET. Chen CH, Muzic RF, Nelson AD, Adler LP. IEEE Trans Med Imaging; 1998 Apr; 17(2):214-27. PubMed ID: 9688153 [Abstract] [Full Text] [Related]
4. PET imaging with yttrium-86: comparison of phantom measurements acquired with different PET scanners before and after applying background subtraction. Buchholz HG, Herzog H, Förster GJ, Reber H, Nickel O, Rösch F, Bartenstein P. Eur J Nucl Med Mol Imaging; 2003 May; 30(5):716-20. PubMed ID: 12605273 [Abstract] [Full Text] [Related]
5. Fast implementation of the single scatter simulation algorithm and its use in iterative image reconstruction of PET data. Werling A, Bublitz O, Doll J, Adam LE, Brix G. Phys Med Biol; 2002 Aug 21; 47(16):2947-60. PubMed ID: 12222858 [Abstract] [Full Text] [Related]
6. Weighted least-squares reconstruction methods for positron emission tomography. Anderson JM, Mair BA, Rao M, Wu CH. IEEE Trans Med Imaging; 1997 Apr 21; 16(2):159-65. PubMed ID: 9101325 [Abstract] [Full Text] [Related]
14. Application of MRI-based partial-volume correction to the analysis of PET images of mu-opioid receptors using statistical parametric mapping. Bencherif B, Stumpf MJ, Links JM, Frost JJ. J Nucl Med; 2004 Mar 21; 45(3):402-8. PubMed ID: 15001679 [Abstract] [Full Text] [Related]
15. Noise reduction in PET attenuation correction by maximum likelihood histogram sharpening of attenuation images. Price JC, Bacharach SL, Freedman N, Carson RE. J Nucl Med; 1996 May 21; 37(5):786-94. PubMed ID: 8965146 [Abstract] [Full Text] [Related]
16. Spatiotemporal reconstruction of list-mode PET data. Nichols TE, Qi J, Asma E, Leahy RM. IEEE Trans Med Imaging; 2002 Apr 21; 21(4):396-404. PubMed ID: 12022627 [Abstract] [Full Text] [Related]
17. Correction of photon attenuation and collimator response for a body-contouring SPECT/CT imaging system. Seo Y, Wong KH, Sun M, Franc BL, Hawkins RA, Hasegawa BH. J Nucl Med; 2005 May 21; 46(5):868-77. PubMed ID: 15872362 [Abstract] [Full Text] [Related]
18. Evaluation of scatter limitation correction: a new method of correcting photopenic artifacts caused by patient motion during whole-body PET/CT imaging. Miwa K, Umeda T, Murata T, Wagatsuma K, Miyaji N, Terauchi T, Koizumi M, Sasaki M. Nucl Med Commun; 2016 Feb 21; 37(2):147-54. PubMed ID: 26440565 [Abstract] [Full Text] [Related]
19. Robust experiment design for estimating myocardial beta adrenergic receptor concentration using PET. Salinas C, Muzic RF, Ernsberger P, Saidel GM. Med Phys; 2007 Jan 21; 34(1):151-65. PubMed ID: 17278500 [Abstract] [Full Text] [Related]