These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Hemolytic anemia following insertion of Ionescu-Shiley mitral valve bioprosthesis. Reddy SB, Pater JL, Pym J, Armstrong PW. Can Med Assoc J; 1984 Dec 15; 131(12):1469-70. PubMed ID: 6498703 [Abstract] [Full Text] [Related]
3. The hole in the valve: presentation with haemolytic anaemia. Terada Y, Mitsui T, Tsutsui T, Asakura T, Abe M. Med J Aust; 1984 Dec 15; 161(11-12):674. PubMed ID: 7830634 [No Abstract] [Full Text] [Related]
4. [Haemolytic anaemia following implantation of the mitral annuloplasty ring: a case report]. Goździk A, Skalik R, Pelczar M, Obremska M, Kustrzycki W. Kardiol Pol; 2006 Jun 15; 64(6):619-21. PubMed ID: 16810582 [Abstract] [Full Text] [Related]
5. Bioprosthetic mitral valve dysfunction due to native valve preserving procedure. Matsuno Y, Mori Y, Umeda Y, Takiya H. Asian Cardiovasc Thorac Ann; 2016 Mar 15; 24(3):276-9. PubMed ID: 25392048 [Abstract] [Full Text] [Related]
6. [Transcatheter valve-in-valve implantation in mitral valve bioprosthesis]. Hirnle T, Dobrzycki S, Frank M, Sobkowicz B, Mitrosz M. Kardiol Pol; 2013 Mar 15; 71(6):661. PubMed ID: 23797451 [No Abstract] [Full Text] [Related]
7. Complete Transcatheter Treatment of Degenerated Bioprosthetic Mitral Regurgitation: Transapical Paravalvular Leak Closure Followed by Transseptal Mitral Valve-in-Valve Replacement. Singh GD, Smith TW, Boyd WD, Southard JA, Wong GB, Philip F, Low RI, Rogers JH. JACC Cardiovasc Interv; 2015 Dec 21; 8(14):e229-31. PubMed ID: 26604059 [No Abstract] [Full Text] [Related]
8. A case of 24 years longevity of an Ionescu-Shiley bioprosthesis in the mitral position. Watanabe Y, Ohkawa S, Yamabuki K, Tsuneoka H, Sugiyama N, Hiyama T. Asian Cardiovasc Thorac Ann; 2006 Oct 21; 14(5):e96-8. PubMed ID: 17005876 [Abstract] [Full Text] [Related]
10. A case of bioprosthetic mitral valve dysfunction presenting as haemolytic anaemia. Chan DK, Cheung GY. Aust N Z J Med; 1995 Oct 21; 25(5):543. PubMed ID: 8588784 [No Abstract] [Full Text] [Related]
11. Transvenous, antegrade Melody valve-in-valve implantation for bioprosthetic mitral and tricuspid valve dysfunction: a case series in children and adults. Cullen MW, Cabalka AK, Alli OO, Pislaru SV, Sorajja P, Nkomo VT, Malouf JF, Cetta F, Hagler DJ, Rihal CS. JACC Cardiovasc Interv; 2013 Jun 21; 6(6):598-605. PubMed ID: 23683739 [Abstract] [Full Text] [Related]
15. The impact of patient-prosthesis mismatch on late outcomes after mitral valve replacement. Lam BK, Chan V, Hendry P, Ruel M, Masters R, Bedard P, Goldstein B, Rubens F, Mesana T. J Thorac Cardiovasc Surg; 2007 Jun 21; 133(6):1464-73. PubMed ID: 17532940 [Abstract] [Full Text] [Related]
16. Fatigue-induced failure of the Ionescu-Shiley pericardial xenograft in the mitral position. In vivo and in vitro correlation and a proposed classification. Gabbay S, Bortolotti U, Wasserman F, Factor S, Strom J, Frater RW. J Thorac Cardiovasc Surg; 1984 Jun 21; 87(6):836-44. PubMed ID: 6727407 [Abstract] [Full Text] [Related]
18. [Hemolysis after bioprosthesis implantation in the mitral valve]. Olszowska M, Hlawaty M, Pfitzner R, Tracz W. Pol Tyg Lek; 1984 Jun 21; 48(3-4):83-4. PubMed ID: 8361896 [Abstract] [Full Text] [Related]
19. Risk of reoperation for mitral bioprosthesis dysfunction. Jaussaud N, Gariboldi V, Grisoli D, Berbis J, Kerbaul F, Riberi A, Collart F. J Heart Valve Dis; 2012 Jan 21; 21(1):56-60. PubMed ID: 22474743 [Abstract] [Full Text] [Related]