These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


275 related items for PubMed ID: 9787903

  • 21. Determination of tramadol and O-desmethyltramadol in human plasma by high-performance liquid chromatography with mass spectrometry detection.
    Vlase L, Leucuta SE, Imre S.
    Talanta; 2008 May 30; 75(4):1104-9. PubMed ID: 18585190
    [Abstract] [Full Text] [Related]

  • 22. High-performance liquid chromatography method for determining alendronate sodium in human plasma by detecting fluorescence: application to a pharmacokinetic study in humans.
    Yun MH, Kwon KI.
    J Pharm Biomed Anal; 2006 Jan 23; 40(1):168-72. PubMed ID: 16095861
    [Abstract] [Full Text] [Related]

  • 23. Development and validation of a new reversed-phase ion pairing liquid chromatographic method with fluorescence detection for penciclovir analysis in plasma and aqueous humor.
    Schenkel F, Rudaz S, Daali Y, Oestreicher MK, Veuthey JL, Dayer P.
    J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Nov 05; 826(1-2):1-7. PubMed ID: 16140045
    [Abstract] [Full Text] [Related]

  • 24. Determination of serotonin, noradrenaline, dopamine and their metabolites in rat brain extracts and microdialysis samples by column liquid chromatography with fluorescence detection following derivatization with benzylamine and 1,2-diphenylethylenediamine.
    Yoshitake T, Kehr J, Yoshitake S, Fujino K, Nohta H, Yamaguchi M.
    J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Aug 05; 807(2):177-83. PubMed ID: 15203027
    [Abstract] [Full Text] [Related]

  • 25. A sensitive assay for the quantitative analysis of vinorelbine in mouse and human EDTA plasma by high-performance liquid chromatography coupled with electrospray tandem mass spectrometry.
    Damen CW, Rosing H, Tibben MM, van Maanen MJ, Lagas JS, Schinkel AH, Schellens JH, Beijnen JH.
    J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Jun 01; 868(1-2):102-9. PubMed ID: 18501686
    [Abstract] [Full Text] [Related]

  • 26. High performance liquid chromatographic method for the determination of sumatriptan with fluorescence detection in human plasma.
    Ge Z, Tessier E, Neirinck L, Zhu Z.
    J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Jul 05; 806(2):299-303. PubMed ID: 15171943
    [Abstract] [Full Text] [Related]

  • 27. A rapid and highly sensitive method for the determination of glimepiride in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry: application to a pre-clinical pharmacokinetic study.
    Chakradhar L, Kallem R, Karthik A, Sundari BT, Ramesh S, Mullangi R, Srinivas NR.
    Biomed Chromatogr; 2008 Jan 05; 22(1):58-63. PubMed ID: 17642067
    [Abstract] [Full Text] [Related]

  • 28. Validation and pharmacokinetic application of a method for determination of doxazosin in human plasma by high-performance liquid chromatography.
    Sripalakit P, Nermhom P, Saraphanchotiwitthaya A.
    Biomed Chromatogr; 2006 Aug 05; 20(8):729-35. PubMed ID: 16235201
    [Abstract] [Full Text] [Related]

  • 29. HPLC method for the determination of fluvoxamine in human plasma and urine for application to pharmacokinetic studies.
    Ulu ST.
    J Pharm Biomed Anal; 2007 Mar 12; 43(4):1444-51. PubMed ID: 17157470
    [Abstract] [Full Text] [Related]

  • 30. Quantitative high-throughput determination of endogenous retinoids in human plasma using triple-stage liquid chromatography/tandem mass spectrometry.
    Gundersen TE, Bastani NE, Blomhoff R.
    Rapid Commun Mass Spectrom; 2007 Mar 12; 21(7):1176-86. PubMed ID: 17330217
    [Abstract] [Full Text] [Related]

  • 31. Determination of moclobemide in human plasma by high-performance liquid chromatography with spectrophotometric detection.
    Amini H, Shahmir B, Ahmadiani A.
    J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Aug 05; 807(2):271-5. PubMed ID: 15203040
    [Abstract] [Full Text] [Related]

  • 32. Sensitive determination of ranitidine in rabbit plasma by HPLC with fluorescence detection.
    Khedr A.
    J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Feb 01; 862(1-2):175-80. PubMed ID: 18166505
    [Abstract] [Full Text] [Related]

  • 33. Rapid and sensitive determination of phenol in honey by high-performance liquid chromatography with fluorescence detection.
    Gyorik M, Herpai Z, Szécsényi I, Varga L, Szigeti J.
    J Agric Food Chem; 2003 Aug 27; 51(18):5222-5. PubMed ID: 12926862
    [Abstract] [Full Text] [Related]

  • 34. Quantitation of itopride in human serum by high-performance liquid chromatography with fluorescence detection and its application to a bioequivalence study.
    Singh SS, Jain M, Sharma K, Shah B, Vyas M, Thakkar P, Shah R, Singh S, Lohray B.
    J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Apr 25; 818(2):213-20. PubMed ID: 15734161
    [Abstract] [Full Text] [Related]

  • 35. Sensitive determination of clarithromycin in human plasma by high-performance liquid chromatography with spectrophotometric detection.
    Amini H, Ahmadiani A.
    J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Mar 25; 817(2):193-7. PubMed ID: 15686985
    [Abstract] [Full Text] [Related]

  • 36. Determination of atrasentan by high performance liquid chromatography with fluorescence detection in human plasma.
    Bryan PD, Sapochak LB, Tames MM, Padley RJ, El-Shourbagy TA.
    Biomed Chromatogr; 2001 Dec 25; 15(8):525-33. PubMed ID: 11748688
    [Abstract] [Full Text] [Related]

  • 37. Validation and application of a high-performance liquid chromatography-tandem mass spectrometric method for simultaneous quantification of lopinavir and ritonavir in human plasma using semi-automated 96-well liquid-liquid extraction.
    Wang PG, Wei JS, Kim G, Chang M, El-Shourbagy T.
    J Chromatogr A; 2006 Oct 20; 1130(2):302-7. PubMed ID: 16919649
    [Abstract] [Full Text] [Related]

  • 38. Quantification of zolpidem in human plasma by high-performance liquid chromatography with fluorescence detection.
    Nirogi RV, Kandikere VN, Shrivasthava W, Mudigonda K.
    Biomed Chromatogr; 2006 Oct 20; 20(10):1103-8. PubMed ID: 16703647
    [Abstract] [Full Text] [Related]

  • 39. Sensitive determination of trimetazidine in spiked human plasma by HPLC with fluorescence detection after pre-column derivatization with 9-fluorenylmethyl chloroformate.
    Khedr A, Sheha MM, Darwish IA.
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Sep 01; 856(1-2):337-42. PubMed ID: 17644495
    [Abstract] [Full Text] [Related]

  • 40. Rapid determination of loratadine in small volume plasma samples by high-performance liquid chromatography with fluorescence detection.
    Amini H, Ahmadiani A.
    J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Oct 05; 809(2):227-30. PubMed ID: 15315769
    [Abstract] [Full Text] [Related]


    Page: [Previous] [Next] [New Search]
    of 14.