These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


72 related items for PubMed ID: 9810336

  • 1. Verification of set-up deviations in patients with breast cancer using portal imaging in clinical practice.
    Böhmer D, Feyer P, Harder C, Körner M, Sternemann M, Dinges S, Budach V.
    Strahlenther Onkol; 1998 Oct; 174 Suppl 2():36-9. PubMed ID: 9810336
    [Abstract] [Full Text] [Related]

  • 2. Interfractional set-up errors evaluation by daily electronic portal imaging of IMRT in head and neck cancer patients.
    Pehlivan B, Pichenot C, Castaing M, Auperin A, Lefkopoulos D, Arriagada R, Bourhis J.
    Acta Oncol; 2009 Oct; 48(3):440-5. PubMed ID: 19031160
    [Abstract] [Full Text] [Related]

  • 3. Treatment accuracy of fractionated stereotactic radiotherapy.
    Kumar S, Burke K, Nalder C, Jarrett P, Mubata C, A'hern R, Humphreys M, Bidmead M, Brada M.
    Radiother Oncol; 2005 Jan; 74(1):53-9. PubMed ID: 15683670
    [Abstract] [Full Text] [Related]

  • 4. The use of magnetic sensors to monitor moderate deep inspiration breath hold during breast irradiation with dynamic MLC compensators.
    Remouchamps VM, Huyskens DP, Mertens I, Destine M, Van Esch A, Salamon E, De Neve W.
    Radiother Oncol; 2007 Mar; 82(3):341-8. PubMed ID: 17207547
    [Abstract] [Full Text] [Related]

  • 5. [Assessment of the accuracy of position in breast irradiation with isocentric technique using an electronic system to acquire portal images].
    Greco C, Brambilla MG, Orecchia R.
    Radiol Med; 1997 Mar; 93(3):254-9. PubMed ID: 9221419
    [Abstract] [Full Text] [Related]

  • 6. Image-guided stereotactic body radiotherapy for lung tumors using BodyLoc with tomotherapy: clinical implementation and set-up accuracy.
    Zhou J, Uhl B, Dewitt K, Young M, Taylor B, Fei DY, Lo YC.
    Med Dosim; 2010 Mar; 35(1):12-8. PubMed ID: 19931009
    [Abstract] [Full Text] [Related]

  • 7. Evaluation of set-up deviations during the irradiation of patients suffering from breast cancer treated with two different techniques.
    Kukołowicz PF, Debrowski A, Gut P, Chmielewski L, Wieczorek A, Kedzierawski P.
    Radiother Oncol; 2005 Apr; 75(1):22-7. PubMed ID: 15878097
    [Abstract] [Full Text] [Related]

  • 8. Analysis of interfractional set-up errors and intrafractional organ motions during IMRT for head and neck tumors to define an appropriate planning target volume (PTV)- and planning organs at risk volume (PRV)-margins.
    Suzuki M, Nishimura Y, Nakamatsu K, Okumura M, Hashiba H, Koike R, Kanamori S, Shibata T.
    Radiother Oncol; 2006 Mar; 78(3):283-90. PubMed ID: 16564594
    [Abstract] [Full Text] [Related]

  • 9. Determination of optimum planning target volume margins for various tumor sites using electronic portal imaging.
    Andrieu MN, Dirican B, Ozturk AY, Hicsonmez A, Kurtman C.
    Exp Oncol; 2004 Sep; 26(3):236-9. PubMed ID: 15494694
    [Abstract] [Full Text] [Related]

  • 10.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 11. Convolution method and CTV-to-PTV margins for finite fractions and small systematic errors.
    Gordon JJ, Siebers JV.
    Phys Med Biol; 2007 Apr 07; 52(7):1967-90. PubMed ID: 17374922
    [Abstract] [Full Text] [Related]

  • 12. [Opto-electronic techniques and 3D body surface reconstruction for the control of patient positioning in the radiotherapy of breast cancer].
    Baroni G, Troia A, Troia A, Orecchia R, Pedotti A.
    Radiol Med; 2001 Sep 07; 102(3):168-77. PubMed ID: 11677460
    [Abstract] [Full Text] [Related]

  • 13. Real-time opto-electronic verification of patient position in breast cancer radiotherapy.
    Baroni G, Ferrigno G, Orecchia R, Pedotti A.
    Comput Aided Surg; 2000 Sep 07; 5(4):296-306. PubMed ID: 11029162
    [Abstract] [Full Text] [Related]

  • 14. Evaluation of set-up errors in head and neck radiotherapy using electronic portal imaging.
    Strbac B, Jokic VS.
    Phys Med; 2013 Sep 07; 29(5):531-6. PubMed ID: 23290565
    [Abstract] [Full Text] [Related]

  • 15. Cone beam CT evaluation of patient set-up accuracy as a QA tool.
    Nielsen M, Bertelsen A, Westberg J, Jensen HR, Brink C.
    Acta Oncol; 2009 Sep 07; 48(2):271-6. PubMed ID: 18759138
    [Abstract] [Full Text] [Related]

  • 16. Breast boost: are we missing the target?
    Benda RK, Yasuda G, Sethi A, Gabram SG, Hinerman RW, Mendenhall NP.
    Cancer; 2003 Feb 15; 97(4):905-9. PubMed ID: 12569589
    [Abstract] [Full Text] [Related]

  • 17. Electronic portal images (EPIs) based position verification for the breast simultaneous integrated boost (SIB) technique.
    Sijtsema NM, van Dijk-Peters FB, Langendijk JA, Maduro JH, van 't Veld AA.
    Radiother Oncol; 2012 Jan 15; 102(1):108-14. PubMed ID: 22098795
    [Abstract] [Full Text] [Related]

  • 18. Verification of the patient positioning in the bellyboard pelvic radiotherapy.
    Kasabasić M, Faj D, Smilović Radojcić D, Svabić M, Ivković A, Jurković S.
    Coll Antropol; 2008 Oct 15; 32 Suppl 2():211-5. PubMed ID: 19140284
    [Abstract] [Full Text] [Related]

  • 19. Patient set-up verification by infrared optical localization and body surface sensing in breast radiation therapy.
    Spadea MF, Baroni G, Riboldi M, Tagaste B, Garibaldi C, Orecchia R, Pedotti A.
    Radiother Oncol; 2006 May 15; 79(2):170-8. PubMed ID: 16574263
    [Abstract] [Full Text] [Related]

  • 20. Measurements of intrafraction motion and interfraction and intrafraction rotation of prostate by three-dimensional analysis of daily portal imaging with radiopaque markers.
    Aubry JF, Beaulieu L, Girouard LM, Aubin S, Tremblay D, Laverdière J, Vigneault E.
    Int J Radiat Oncol Biol Phys; 2004 Sep 01; 60(1):30-9. PubMed ID: 15337537
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 4.