21. Level of blood pressure control in a hypertensive population when measurements are performed outside the clinical setting. Félix-Redondo FJ, Fernández-Bergés D, Espinosa-Garcia J, Pozuelos-Estrada J, Molina-Martínez LM, Pérez-Castán JF, Ríos-Rivera J, Valiente-Rubio JI, Gómez-de-la-Cámara A, Rodríguez-Pascual N. Cardiol J; 2009; 16(1):57-67. PubMed ID: 19130417 [Abstract] [Full Text] [Related]
23. My blood pressure is normal. Why does my doctor want me to wear a BP monitor? Johns Hopkins Med Lett Health After 50; 2010 Apr; 22(2):8. PubMed ID: 20480976 [No Abstract] [Full Text] [Related]
24. Misclassification of blood pressure by usual measurement in ambulatory physician practices. Campbell NR, Culleton BW, McKay DW. Am J Hypertens; 2005 Dec; 18(12 Pt 1):1522-7. PubMed ID: 16364819 [Abstract] [Full Text] [Related]
25. Ambulatory blood pressure monitoring: another tool for the diagnosis and management of hypertension. Hegg AM. S D Med; 2009 Oct; 62(10):400-1. PubMed ID: 19856828 [Abstract] [Full Text] [Related]
26. White coat hypertension in adolescents. Koch VH, Furusawa EA, Saito MI, Colli A, Ignes EC, Okay Y, Mion Júnior D. Clin Nephrol; 1999 Nov; 52(5):297-303. PubMed ID: 10584993 [Abstract] [Full Text] [Related]
27. Repeated office blood pressure controls reduce the prevalence of white-coat hypertension and detect a group of white-coat normotensive patients. Fogari R, Corradi L, Zoppi A, Lusardi P, Poletti L. Blood Press Monit; 1996 Feb; 1(1):51-54. PubMed ID: 10226202 [Abstract] [Full Text] [Related]
28. Lack of association between body-mass index and white-coat hypertension among referred patients. Ben-Dov IZ, Mekler J, Ben-Arie L, Bursztyn M. Blood Press Monit; 2007 Apr; 12(2):95-9. PubMed ID: 17353652 [Abstract] [Full Text] [Related]
29. White-coat hypertension. Rapoport D. CMAJ; 1999 Nov 02; 161(9):1101-2. PubMed ID: 10569083 [No Abstract] [Full Text] [Related]
30. By the way, doctor... My blood pressure is high in my doctor's office, but low when I take it at home on my blood-pressure monitor. My doctor says that I have white-coat hypertension, blood pressure that goes up in a doctor's office. She says it isn't medically dangerous, but can that be true? Lee TH. Harv Health Lett; 2000 Aug 02; 25(10):8. PubMed ID: 10927815 [No Abstract] [Full Text] [Related]
31. Patient self-monitoring of blood pressure in general practice: the 'inverse white-coat' response. Turnbull SM, Magennis SP, Turnbull CJ. Br J Gen Pract; 2003 Mar 02; 53(488):221-3. PubMed ID: 14694700 [Abstract] [Full Text] [Related]
32. Prevalence and predictors of white-coat hypertension in a large database of ambulatory blood pressure monitoring. Abir-Khalil S, Zaîmi S, Tazi MA, Bendahmane S, Bensaoud O, Benomar M. East Mediterr Health J; 2009 Mar 02; 15(2):400-7. PubMed ID: 19554987 [Abstract] [Full Text] [Related]
33. ["White coat" hypertension]. Gadzhiev AN. Klin Med (Mosk); 2004 Mar 02; 82(2):15-9. PubMed ID: 15106504 [Abstract] [Full Text] [Related]
34. Masked hypertension assessed by ambulatory blood pressure versus home blood pressure monitoring: is it the same phenomenon? Stergiou GS, Salgami EV, Tzamouranis DG, Roussias LG. Am J Hypertens; 2005 Jun 02; 18(6):772-8. PubMed ID: 15925734 [Abstract] [Full Text] [Related]
35. Home blood pressure is as reliable as ambulatory blood pressure in predicting target-organ damage in hypertension. Stergiou GS, Argyraki KK, Moyssakis I, Mastorantonakis SE, Achimastos AD, Karamanos VG, Roussias LG. Am J Hypertens; 2007 Jun 02; 20(6):616-21. PubMed ID: 17531917 [Abstract] [Full Text] [Related]
36. Reproducibility of white-coat and masked hypertension in ambulatory BP monitoring. Ben-Dov IZ, Ben-Arie L, Mekler J, Bursztyn M. Int J Cardiol; 2007 May 02; 117(3):355-9. PubMed ID: 16879886 [Abstract] [Full Text] [Related]
37. Detecting white coat and reverse white coat effects in clinic settings using measures of blood pressure habituation in the clinic and patient self-monitoring of blood pressure. Larkin KT, Schauss SL, Elnicki DM, Goodie JL. J Hum Hypertens; 2007 Jul 02; 21(7):516-24. PubMed ID: 17361194 [Abstract] [Full Text] [Related]
38. [Arterial hypertension difficult to control in the elderly patient. The significance of the "white coat effect"]. Amado P, Vasconcelos N, Santos I, Almeida L, Nazaré J, Carmona J. Rev Port Cardiol; 1999 Oct 02; 18(10):897-906. PubMed ID: 10590654 [Abstract] [Full Text] [Related]
39. 'Office-hour' ambulatory blood pressure monitoring is sufficient for blood pressure diagnosis. Wong RC, Yeo TC. J Hum Hypertens; 2006 Jun 02; 20(6):440-3. PubMed ID: 16598289 [Abstract] [Full Text] [Related]
40. [Practical questions related to self-measurement of blood pressure]. Verberk WJ, Kroon AA, de Leeuw PW. Ned Tijdschr Geneeskd; 2008 Mar 08; 152(10):546-9. PubMed ID: 18402319 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]