BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

647 related articles for article (PubMed ID: 20619553)

  • 1. Adaptive planning in intensity-modulated radiation therapy for head and neck cancers: single-institution experience and clinical implications.
    Ahn PH; Chen CC; Ahn AI; Hong L; Scripes PG; Shen J; Lee CC; Miller E; Kalnicki S; Garg MK
    Int J Radiat Oncol Biol Phys; 2011 Jul; 80(3):677-85. PubMed ID: 20619553
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Computed tomography number changes observed during computed tomography-guided radiation therapy for head and neck cancer.
    Feng M; Yang C; Chen X; Xu S; Moraru I; Lang J; Schultz C; Li XA
    Int J Radiat Oncol Biol Phys; 2015 Apr; 91(5):1041-7. PubMed ID: 25832695
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Near Real-Time Assessment of Anatomic and Dosimetric Variations for Head and Neck Radiation Therapy via Graphics Processing Unit-based Dose Deformation Framework.
    Qi XS; Santhanam A; Neylon J; Min Y; Armstrong T; Sheng K; Staton RJ; Pukala J; Pham A; Low DA; Lee SP; Steinberg M; Manon R; Chen AM; Kupelian P
    Int J Radiat Oncol Biol Phys; 2015 Jun; 92(2):415-22. PubMed ID: 25847607
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Monitoring dosimetric impact of weight loss with kilovoltage (kV) cone beam CT (CBCT) during parotid-sparing IMRT and concurrent chemotherapy.
    Ho KF; Marchant T; Moore C; Webster G; Rowbottom C; Penington H; Lee L; Yap B; Sykes A; Slevin N
    Int J Radiat Oncol Biol Phys; 2012 Mar; 82(3):e375-82. PubMed ID: 22197229
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A clinical concept for interfractional adaptive radiation therapy in the treatment of head and neck cancer.
    Jensen AD; Nill S; Huber PE; Bendl R; Debus J; Münter MW
    Int J Radiat Oncol Biol Phys; 2012 Feb; 82(2):590-6. PubMed ID: 21310549
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dependence of achievable plan quality on treatment technique and planning goal refinement: a head-and-neck intensity modulated radiation therapy application.
    Qi XS; Ruan D; Lee SP; Pham A; Kupelian P; Low DA; Steinberg M; Demarco J
    Int J Radiat Oncol Biol Phys; 2015 Mar; 91(4):817-24. PubMed ID: 25752396
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Daily kV cone-beam CT and deformable image registration as a method for studying dosimetric consequences of anatomic changes in adaptive IMRT of head and neck cancer.
    Elstrøm UV; Wysocka BA; Muren LP; Petersen JB; Grau C
    Acta Oncol; 2010 Oct; 49(7):1101-8. PubMed ID: 20831502
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A Study to Assess the Dosimetric Impact of the Anatomical Changes Occurring in the Parotid Glands and Tumour Volume during Intensity Modulated Radiotherapy using Simultaneous Integrated Boost (IMRT-SIB) in Head and Neck Squamous Cell Cancers.
    Ghosh A; Gupta S; Johny D; Vidyadhar Bhosale V; Pal Singh Negi M
    Cancer Med; 2021 Aug; 10(15):5175-5190. PubMed ID: 34159749
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dosimetric Evaluation of Incorporating Patient Geometric Variations Into Adaptive Plan Optimization Through Probabilistic Treatment Planning in Head and Neck Cancers.
    Liu Q; Liang J; Zhou D; Krauss DJ; Chen PY; Yan D
    Int J Radiat Oncol Biol Phys; 2018 Jul; 101(4):985-997. PubMed ID: 29976511
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Data-driven approach to generating achievable dose-volume histogram objectives in intensity-modulated radiotherapy planning.
    Wu B; Ricchetti F; Sanguineti G; Kazhdan M; Simari P; Jacques R; Taylor R; McNutt T
    Int J Radiat Oncol Biol Phys; 2011 Mar; 79(4):1241-7. PubMed ID: 20800382
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Relative plan robustness of step-and-shoot vs rotational intensity-modulated radiotherapy on repeat computed tomographic simulation for weight loss in head and neck cancer.
    Thomson DJ; Beasley WJ; Garcez K; Lee LW; Sykes AJ; Rowbottom CG; Slevin NJ
    Med Dosim; 2016; 41(2):154-8. PubMed ID: 26993081
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Repeat CT imaging and replanning during the course of IMRT for head-and-neck cancer.
    Hansen EK; Bucci MK; Quivey JM; Weinberg V; Xia P
    Int J Radiat Oncol Biol Phys; 2006 Feb; 64(2):355-62. PubMed ID: 16256277
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intensity modulated arc therapy implementation in a three phase adaptive (18)F-FDG-PET voxel intensity-based planning strategy for head-and-neck cancer.
    Berwouts D; Olteanu LA; Speleers B; Duprez F; Madani I; Vercauteren T; De Neve W; De Gersem W
    Radiat Oncol; 2016 Apr; 11():52. PubMed ID: 27039294
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Adaptive replanning strategies accounting for shrinkage in head and neck IMRT.
    Wu Q; Chi Y; Chen PY; Krauss DJ; Yan D; Martinez A
    Int J Radiat Oncol Biol Phys; 2009 Nov; 75(3):924-32. PubMed ID: 19801104
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Volume and dosimetric changes and initial clinical experience of a two-step adaptive intensity modulated radiation therapy (IMRT) scheme for head and neck cancer.
    Nishi T; Nishimura Y; Shibata T; Tamura M; Nishigaito N; Okumura M
    Radiother Oncol; 2013 Jan; 106(1):85-9. PubMed ID: 23337058
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The residual setup errors of different IGRT alignment procedures for head and neck IMRT and the resulting dosimetric impact.
    Graff P; Kirby N; Weinberg V; Chen J; Yom SS; Lambert L; Pouliot J
    Int J Radiat Oncol Biol Phys; 2013 May; 86(1):170-6. PubMed ID: 23245281
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Target and organ dose estimation from intensity modulated head and neck radiation therapy using 3 deformable image registration algorithms.
    Kumarasiri A; Liu C; Siddiqui F; Zhong H; Chetty IJ; Kim J
    Pract Radiat Oncol; 2015; 5(4):e317-25. PubMed ID: 25752720
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Volumetric and positional changes of planning target volumes and organs at risk using computed tomography imaging during intensity-modulated radiation therapy for head-neck cancer: an "old" adaptive radiation therapy approach.
    Reali A; Anglesio SM; Mortellaro G; Allis S; Bartoncini S; Ruo Redda MG; Arcadipane F
    Radiol Med; 2014 Sep; 119(9):714-20. PubMed ID: 24510758
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A novel surrogate to identify anatomical changes during radiotherapy of head and neck cancer patients.
    Gros SA; Xu W; Roeske JC; Choi M; Emami B; Surucu M
    Med Phys; 2017 Mar; 44(3):924-934. PubMed ID: 28019647
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Will weight loss cause significant dosimetric changes of target volumes and organs at risk in nasopharyngeal carcinoma treated with intensity-modulated radiation therapy?
    Chen C; Fei Z; Chen L; Bai P; Lin X; Pan J
    Med Dosim; 2014; 39(1):34-7. PubMed ID: 24140235
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 33.