205 related articles for article (PubMed ID: 27033545)
1. A Case Series: Outcomes of Endoscopic Biliary Self-Expandable Metal Stent for Malignant Biliary Obstruction with Surgically Altered Anatomy.
Yamauchi H; Kida M; Okuwaki K; Miyazawa S; Iwai T; Imaizumi H; Eiji M; Hasegawa R; Koizumi W
Dig Dis Sci; 2016 Aug; 61(8):2436-2441. PubMed ID: 27033545
[TBL] [Abstract][Full Text] [Related]
2. Safety and efficacy of a metal stent covered with a silicone membrane containing integrated silver particles in preventing biofilm and sludge formation in endoscopic drainage of malignant biliary obstruction: a phase 2 pilot study.
Lee TH; Jung MK; Kim TK; Pack CG; Park YK; Kim SO; Park DH
Gastrointest Endosc; 2019 Oct; 90(4):663-672.e2. PubMed ID: 31220446
[TBL] [Abstract][Full Text] [Related]
3. Combined side-by-side and stent-in-stent method for triple metal stenting in patients with malignant hilar biliary obstruction.
Inoue T; Ibusuki M; Kitano R; Kobayashi Y; Ohashi T; Nakade Y; Sumida Y; Ito K; Nakao H; Yoneda M
Dig Endosc; 2019 Nov; 31(6):698-705. PubMed ID: 31120163
[TBL] [Abstract][Full Text] [Related]
4. Single-stage EUS-guided choledochoduodenostomy using a lumen-apposing metal stent for malignant distal biliary obstruction.
Anderloni A; Fugazza A; Troncone E; Auriemma F; Carrara S; Semeraro R; Maselli R; Di Leo M; D'Amico F; Sethi A; Repici A
Gastrointest Endosc; 2019 Jan; 89(1):69-76. PubMed ID: 30189198
[TBL] [Abstract][Full Text] [Related]
5. Utility and Safety of a Novel Fully Covered Metal Stent in Unresectable Distal Malignant Biliary Obstruction.
Yamao K; Takenaka M; Ogura T; Hashimoto H; Matsumoto H; Yamamoto M; Ikeura T; Kurita A; Li ZL; Shiomi H; Chiba Y; Kudo M; Sanuki T
Dig Dis Sci; 2020 Dec; 65(12):3702-3709. PubMed ID: 32036515
[TBL] [Abstract][Full Text] [Related]
6. Adverse events of self-expandable metal stent placement for malignant distal biliary obstruction: a large multicenter study.
Tamura T; Yamai T; Uza N; Yamasaki T; Masuda A; Tomooka F; Maruyama H; Shigekawa M; Ogura T; Kuriyama K; Asada M; Matsumoto H; Takenaka M; Mandai K; Osaki Y; Matsumoto K; Sanuki T; Shiomi H; Yamagata Y; Doi T; Inatomi O; Nakanishi F; Emori T; Shimatani M; Asai S; Fujigaki S; Shimokawa T; Kitano M
Gastrointest Endosc; 2024 Jan; 99(1):61-72.e8. PubMed ID: 37598864
[TBL] [Abstract][Full Text] [Related]
7. Revision of bilateral self-expandable metallic stents placed using the stent-in-stent technique for malignant hilar biliary obstruction.
Son JH; Lee HS; Lee SH; Bang S; Kang J; Paik WH; Ryu JK; Kim YT
Hepatobiliary Pancreat Dis Int; 2018 Oct; 17(5):437-442. PubMed ID: 30082195
[TBL] [Abstract][Full Text] [Related]
8. Evaluation of endoscopic reintervention for self-expandable metallic stent obstruction after stent-in-stent placement for malignant hilar biliary obstruction.
Okuno M; Mukai T; Iwashita T; Ichikawa H; Iwasa Y; Mita N; Yoshida K; Iwata K; Tomita E; Shimizu M
J Hepatobiliary Pancreat Sci; 2019 Jun; 26(6):211-218. PubMed ID: 30950234
[TBL] [Abstract][Full Text] [Related]
9. Clinical Outcomes of Bilateral Stent-in-Stent Placement Using Self-Expandable Metallic Stent for High-Grade Malignant Hilar Biliary Obstruction.
Heo JY; Lee HS; Son JH; Lee SH; Bang S
Yonsei Med J; 2018 Sep; 59(7):827-833. PubMed ID: 30091315
[TBL] [Abstract][Full Text] [Related]
10. Novel concept of bared type metallic stent for endoscopic bilateral stent-in-stent placement in patients with hilar malignant biliary obstruction (with video).
Takenaka M; Nakai A; Kudo M
J Hepatobiliary Pancreat Sci; 2020 May; 27(5):282-283. PubMed ID: 31702100
[TBL] [Abstract][Full Text] [Related]
11. Covered and uncovered biliary metal stents provide similar relief of biliary obstruction during neoadjuvant therapy in pancreatic cancer: a randomized trial.
Seo DW; Sherman S; Dua KS; Slivka A; Roy A; Costamagna G; Deviere J; Peetermans J; Rousseau M; Nakai Y; Isayama H; Kozarek R;
Gastrointest Endosc; 2019 Oct; 90(4):602-612.e4. PubMed ID: 31276674
[TBL] [Abstract][Full Text] [Related]
12. Efficacy of multi-hole self-expandable metal stent compared to fully covered and uncovered self-expandable metal stents in patients with unresectable malignant distal biliary obstruction: a propensity analysis.
Kulpatcharapong S; Piyachaturawat P; Mekaroonkamol P; Angsuwatcharakon P; Ridtitid W; Kongkam P; Rerknimitr R
Surg Endosc; 2024 Jan; 38(1):212-221. PubMed ID: 37964091
[TBL] [Abstract][Full Text] [Related]
13. Distal malignant biliary obstruction: a prospective randomised trial comparing plastic and uncovered self-expanding metal stents in the palliation of symptomatic jaundice.
Bernon MM; Shaw J; Burmeister S; Chinnery G; Hofmeyr S; Kloppers JC; Jonas E; Krige JE
S Afr J Surg; 2018 Mar; 56(1):30-34. PubMed ID: 29638090
[TBL] [Abstract][Full Text] [Related]
14. Retrospective comparison of different percutaneous approaches to manage occluded primary uncovered self-expandable metal stents in patients with unresectable malignant hilar biliary obstruction.
Zhang JX; Liu J; Wang B; Liu S; Zu QQ; Shi HB
Scand J Gastroenterol; 2019 Nov; 54(11):1397-1402. PubMed ID: 31656114
[No Abstract] [Full Text] [Related]
15. Comparison of 8- and 10-mm diameter fully covered self-expandable metal stents: A multicenter prospective study in patients with distal malignant biliary obstruction.
Kawashima H; Hashimoto S; Ohno E; Ishikawa T; Morishima T; Matsubara H; Sugimoto H; Nonogaki K; Kanamori A; Hara K; Kuwahara T; Nakamura M; Miyahara R; Ishigami M; Ando M; Hirooka Y;
Dig Endosc; 2019 Jul; 31(4):439-447. PubMed ID: 30714216
[TBL] [Abstract][Full Text] [Related]
16. Analysis of the factors involved in procedural failure: Endoscopic retrograde cholangiopancreatography using a short-type single-balloon enteroscope for patients with surgically altered gastrointestinal anatomy.
Tanisaka Y; Ryozawa S; Mizuide M; Harada M; Fujita A; Ogawa T; Nonaka K; Tashima T; Araki R
Dig Endosc; 2019 Nov; 31(6):682-689. PubMed ID: 30942924
[TBL] [Abstract][Full Text] [Related]
17. Combination of endoscopic retrograde cholangiopancreatography and endoscopic ultrasonography-guided biliary drainage in malignant hilar biliary obstruction.
Kongkam P; Tasneem AA; Rerknimitr R
Dig Endosc; 2019 Apr; 31 Suppl 1():50-54. PubMed ID: 30994233
[TBL] [Abstract][Full Text] [Related]
18. Efficacy and safety of compound tri-metal stent placement for malignant perihilar biliary obstruction.
Kim KM; Jeong CU; Shim SG; Jang H; Song YG; Kim TG; Ji JH
Niger J Clin Pract; 2018 Sep; 21(9):1121-1126. PubMed ID: 30156195
[TBL] [Abstract][Full Text] [Related]
19. Side-by-side placement of fully covered self-expandable metal stents for malignant distal biliary obstruction.
Hirata K; Kuwatani M; Hirata H; Sugiura R; Kato S; Sakamoto N
Clin J Gastroenterol; 2020 Jun; 13(3):455-458. PubMed ID: 31654231
[TBL] [Abstract][Full Text] [Related]
20. Short-type single balloon enteroscope for endoscopic retrograde cholangiopancreatography with altered gastrointestinal anatomy.
Yamauchi H; Kida M; Okuwaki K; Miyazawa S; Iwai T; Takezawa M; Kikuchi H; Watanabe M; Imaizumi H; Koizumi W
World J Gastroenterol; 2013 Mar; 19(11):1728-35. PubMed ID: 23555161
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]