BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

245 related articles for article (PubMed ID: 32794632)

  • 1. Correlation of clinical outcome, radiobiological modeling of tumor control, normal tissue complication probability in lung cancer patients treated with SBRT using Monte Carlo calculation algorithm.
    Sood SS; Pokhrel D; Badkul R; TenNapel M; McClinton C; Kimler B; Wang F
    J Appl Clin Med Phys; 2020 Oct; 21(10):56-62. PubMed ID: 32794632
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Assessment of Monte Carlo algorithm for compliance with RTOG 0915 dosimetric criteria in peripheral lung cancer patients treated with stereotactic body radiotherapy.
    Pokhrel D; Sood S; Badkul R; Jiang H; McClinton C; Lominska C; Kumar P; Wang F
    J Appl Clin Med Phys; 2016 May; 17(3):277-293. PubMed ID: 27167284
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Radiobiological impact of dose calculation algorithms on biologically optimized IMRT lung stereotactic body radiation therapy plans.
    Liang X; Penagaricano J; Zheng D; Morrill S; Zhang X; Corry P; Griffin RJ; Han EY; Hardee M; Ratanatharathom V
    Radiat Oncol; 2016 Jan; 11():10. PubMed ID: 26800883
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Use of a second-dose calculation algorithm to check dosimetric parameters for the dose distribution of a first-dose calculation algorithm for lung SBRT plans.
    Tsuruta Y; Nakamura M; Miyabe Y; Nakata M; Ishihara Y; Mukumoto N; Akimoto M; Ono T; Yano S; Higashimura K; Matsuo Y; Mizowaki T; Hiraoka M
    Phys Med; 2017 Dec; 44():86-95. PubMed ID: 28760507
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Differences in dose-volumetric data between the analytical anisotropic algorithm and the x-ray voxel Monte Carlo algorithm in stereotactic body radiation therapy for lung cancer.
    Mampuya WA; Matsuo Y; Nakamura A; Nakamura M; Mukumoto N; Miyabe Y; Narabayashi M; Sakanaka K; Mizowaki T; Hiraoka M
    Med Dosim; 2013; 38(1):95-9. PubMed ID: 23246194
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Voxel-Level BED Corrected Dosimetric and Radiobiological Assessment of 2 Kinds of Hybrid Radiotherapy Planning Methods for Stage III NSCLC.
    Wang H; Huang Y; Chen H; Shao Y; Duan Y; Feng A; Gu H; Ma X; Xu Z; Kong Q; Zhou Y
    Technol Cancer Res Treat; 2022; 21():15330338221107966. PubMed ID: 35731648
    [No Abstract]   [Full Text] [Related]  

  • 7. Monte Carlo evaluation of tissue heterogeneities corrections in the treatment of head and neck cancer patients using stereotactic radiotherapy.
    Pokhrel D; McClinton C; Sood S; Badkul R; Saleh H; Jiang H; Lominska C
    J Appl Clin Med Phys; 2016 Mar; 17(2):258-270. PubMed ID: 27074489
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dosimetric comparison of lung stereotactic body radiotherapy treatment plans using averaged computed tomography and end-exhalation computed tomography images: Evaluation of the effect of different dose-calculation algorithms and prescription methods.
    Mitsuyoshi T; Nakamura M; Matsuo Y; Ueki N; Nakamura A; Iizuka Y; Mampuya WA; Mizowaki T; Hiraoka M
    Med Dosim; 2016 Winter; 41(4):305-309. PubMed ID: 27623737
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Radiobiological and dosimetric impact of RayStation pencil beam and Monte Carlo algorithms on intensity-modulated proton therapy breast cancer plans.
    Rana S; Greco K; Samuel EJJ; Bennouna J
    J Appl Clin Med Phys; 2019 Aug; 20(8):36-46. PubMed ID: 31343826
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of pencil beam-based homogeneous vs inhomogeneous target dose planning for stereotactic body radiotherapy of peripheral lung tumors through Monte Carlo-based recalculation.
    Ohtakara K; Hoshi H
    Med Dosim; 2015; 40(3):248-55. PubMed ID: 25776903
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dosimetric comparison of Acuros XB, AAA, and XVMC in stereotactic body radiotherapy for lung cancer.
    Tsuruta Y; Nakata M; Nakamura M; Matsuo Y; Higashimura K; Monzen H; Mizowaki T; Hiraoka M
    Med Phys; 2014 Aug; 41(8):081715. PubMed ID: 25086525
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Stereotactic body radiation therapy for stage I non-small cell lung cancer: The importance of treatment planning algorithm and evaluation of a tumor control probability model.
    Ohri N; Tomé W; Kalnicki S; Garg M
    Pract Radiat Oncol; 2018; 8(2):e33-e39. PubMed ID: 29233523
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Stereotactic, single-dose irradiation of lung tumors: a comparison of absolute dose and dose distribution between pencil beam and Monte Carlo algorithms based on actual patient CT scans.
    Chen H; Lohr F; Fritz P; Wenz F; Dobler B; Lorenz F; Mühlnickel W
    Int J Radiat Oncol Biol Phys; 2010 Nov; 78(3):955-63. PubMed ID: 20171796
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Clinical introduction of Monte Carlo treatment planning for lung stereotactic body radiotherapy.
    Miura H; Masai N; Oh RJ; Shiomi H; Yamada K; Sasaki J; Inoue T
    J Appl Clin Med Phys; 2014 Jan; 15(1):4202. PubMed ID: 24423832
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Investigation of four-dimensional (4D) Monte Carlo dose calculation in real-time tumor tracking stereotatic body radiotherapy for lung cancers.
    Chan MK; Kwong DL; Ng SC; Tam EK; Tong AS
    Med Phys; 2012 Sep; 39(9):5479-87. PubMed ID: 22957615
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Correlation of dose computed using different algorithms with local control following stereotactic ablative radiotherapy (SABR)-based treatment of non-small-cell lung cancer.
    Chetty IJ; Devpura S; Liu D; Chen D; Li H; Wen NW; Kumar S; Fraser C; Siddiqui MS; Ajlouni M; Movsas B
    Radiother Oncol; 2013 Dec; 109(3):498-504. PubMed ID: 24231237
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Radiobiological modeling of two stereotactic body radiotherapy schedules in patients with stage I peripheral non-small cell lung cancer.
    Huang BT; Lin Z; Lin PX; Lu JY; Chen CZ
    Oncotarget; 2016 Jun; 7(26):40746-40755. PubMed ID: 27203739
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Still equivalent for dose calculation in the Monte Carlo era? A comparison of free breathing and average intensity projection CT datasets for lung SBRT using three generations of dose calculation algorithms.
    Zvolanek K; Ma R; Zhou C; Liang X; Wang S; Verma V; Zhu X; Zhang Q; Driewer J; Lin C; Zhen W; Wahl A; Zhou SM; Zheng D
    Med Phys; 2017 May; 44(5):1939-1947. PubMed ID: 28273341
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Adapted Prescription Dose for Monte Carlo Algorithm in Lung SBRT: Clinical Outcome on 205 Patients.
    Bibault JE; Mirabel X; Lacornerie T; Tresch E; Reynaert N; Lartigau E
    PLoS One; 2015; 10(7):e0133617. PubMed ID: 26207808
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of heterogeneity dose distributions for Stereotactic Radiotherapy (SRT): comparison of commercially available Monte Carlo dose calculation with other algorithms.
    Takahashi W; Yamashita H; Saotome N; Iwai Y; Sakumi A; Haga A; Nakagawa K
    Radiat Oncol; 2012 Feb; 7():20. PubMed ID: 22315950
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.