215 related articles for article (PubMed ID: 34438276)
1. Occupational and patients effective radiation doses in dental imaging.
Tamam N; Almuqrin AH; Mansour S; Elnour A; Musa M; Omer H; Sulieman A; Bradley DA
Appl Radiat Isot; 2021 Nov; 177():109899. PubMed ID: 34438276
[TBL] [Abstract][Full Text] [Related]
2. Absorbed doses for patients undergoing panoramic radiography, cephalometric radiography and CBCT.
Wrzesień M; Olszewski J
Int J Occup Med Environ Health; 2017 Jul; 30(5):705-713. PubMed ID: 28584324
[TBL] [Abstract][Full Text] [Related]
3. Cone beam computed tomography for dental and maxillofacial imaging: technique improvement and low-dose protocols.
Feragalli B; Rampado O; Abate C; Macrì M; Festa F; Stromei F; Caputi S; Guglielmi G
Radiol Med; 2017 Aug; 122(8):581-588. PubMed ID: 28365888
[TBL] [Abstract][Full Text] [Related]
4. Ionizing Radiation Dose Exposure to the Ocular Region of Pain Physicians During C-arm Guided Pain Interventions.
Kelly R; McMahon A; Hegarty D
Pain Physician; 2018 Sep; 21(5):E523-E532. PubMed ID: 30282400
[TBL] [Abstract][Full Text] [Related]
5. Occupational doses to the eye lens in pediatric and adult noncardiac interventional radiology procedures.
Morcillo AB; Alejo L; Huerga C; Bayón J; Marín A; Corredoira E; Novo JR; Hernández T; Ponce MD; Garzón G; Vañó E; Guibelalde E
Med Phys; 2021 Apr; 48(4):1956-1966. PubMed ID: 33544901
[TBL] [Abstract][Full Text] [Related]
6. Occupational radiation exposure of health professionals and cancer risk assessment for Lithuanian nuclear medicine workers.
Adliene D; Griciene B; Skovorodko K; Laurikaitiene J; Puiso J
Environ Res; 2020 Apr; 183():109144. PubMed ID: 32028181
[TBL] [Abstract][Full Text] [Related]
7. Assessment of patient and occupational exposure and radiation risk from cath-lab procedure.
Sulieman A; Mahgoub O; Salah H; Tamam N; Taha A; Dawood S; Bradley DA
Appl Radiat Isot; 2023 Dec; 202():111071. PubMed ID: 37871398
[TBL] [Abstract][Full Text] [Related]
8. Assessment of Regional Diagnostic Reference Levels in Dental Radiography in Tamil Nadu.
Jose A; Kumar AS; Govindarajan KN; Sharma SD
J Med Phys; 2022; 47(1):86-92. PubMed ID: 35548027
[TBL] [Abstract][Full Text] [Related]
9. PATIENT DOSES IN COMMON DIAGNOSTIC X-RAY EXAMINATIONS.
Metaxas VI; Messaris GA; Lekatou AN; Petsas TG; Panayiotakis GS
Radiat Prot Dosimetry; 2019 Jul; 184(1):12-27. PubMed ID: 30289498
[TBL] [Abstract][Full Text] [Related]
10. ESTIMATION OF EFFECTIVE DOSE OF DENTAL X-RAY DEVICES.
Qiang W; Qiang F; Lin L
Radiat Prot Dosimetry; 2019 Jun; 183(4):417-421. PubMed ID: 30169836
[TBL] [Abstract][Full Text] [Related]
11. Radiation exposure to foetus and breasts from dental X-ray examinations: effect of lead shields.
Kelaranta A; Ekholm M; Toroi P; Kortesniemi M
Dentomaxillofac Radiol; 2016; 45(1):20150095. PubMed ID: 26313308
[TBL] [Abstract][Full Text] [Related]
12. Conversion coefficients for the estimation of effective doses in intraoral and panoramic dental radiology from dose-area product values.
Looe HK; Eenboom F; Chofor N; Pfaffenberger A; Steinhoff M; Rühmann A; Poplawski A; Willborn K; Poppe B
Radiat Prot Dosimetry; 2008; 131(3):365-73. PubMed ID: 18550517
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of the annual occupational effective doses in a SPECT/CT department.
Aamry A; Sulieman A; Tamam N; Abuhadi NH; Johary Y; Aamri H; Mattar E; Salah H; Osman H; Khandaker MU; Bradley D
Appl Radiat Isot; 2022 Mar; 181():110097. PubMed ID: 35063867
[TBL] [Abstract][Full Text] [Related]
14. Is dosimetry still a necessity in current dental practice?
Reddy SS; Rakesh N; Chauhan P; Clint JB; Sharma S
J Radiol Prot; 2015 Dec; 35(4):911-6. PubMed ID: 26619179
[TBL] [Abstract][Full Text] [Related]
15. Radiation dose in dental radiology.
Cohnen M; Kemper J; Möbes O; Pawelzik J; Mödder U
Eur Radiol; 2002 Mar; 12(3):634-7. PubMed ID: 11870479
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of patient and staff doses during various CT fluoroscopy guided interventions.
Buls N; Pagés J; de Mey J; Osteaux M
Health Phys; 2003 Aug; 85(2):165-73. PubMed ID: 12938963
[TBL] [Abstract][Full Text] [Related]
17. Cone-beam computed tomography imaging: therapeutic staff dose during chemoembolisation procedure.
Paul J; Chacko A; Mbalisike EC; Vogl TJ
J Radiol Prot; 2014 Dec; 34(4):843-51. PubMed ID: 25614915
[TBL] [Abstract][Full Text] [Related]
18. Assessment of annual whole-body occupational radiation exposure in medical practice in Ghana (2000-09).
Hasford F; Owusu-Banahene J; Amoako JK; Otoo F; Darko EO; Emi-Reynolds G; Yeboah J; Arwui CC; Adu S
Radiat Prot Dosimetry; 2012 May; 149(4):431-7. PubMed ID: 21743072
[TBL] [Abstract][Full Text] [Related]
19. A multicenter study of radiation doses to the eye lenses of medical staff performing non-vascular imaging and interventional radiology procedures in Japan.
Matsubara K; Takei Y; Mori H; Kobayashi I; Noto K; Igarashi T; Suzuki S; Akahane K
Phys Med; 2020 Jun; 74():83-91. PubMed ID: 32446173
[TBL] [Abstract][Full Text] [Related]
20. Dose reduction in maxillofacial imaging using low dose Cone Beam CT.
Tsiklakis K; Donta C; Gavala S; Karayianni K; Kamenopoulou V; Hourdakis CJ
Eur J Radiol; 2005 Dec; 56(3):413-7. PubMed ID: 15978765
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]